DOI 10.1097/brs.0000000000004088
Prospective Investigation of Postoperative Complications in Anterior Decompression with Fusion for Severe Cervical Ossification of the Posterior Longitudinal Ligament: A Multi-institutional Study.
Аннотация
STUDY
DESIGN
A prospective multicenter study.
OBJECTIVE
This study aims to investigate the postoperative complications of anterior decompression with fusion (ADF) for the treatment of cervical ossification of the posterior longitudinal ligament (OPLL).
SUMMARY OF BACKGROUND DATA: Surgical treatment for cervical OPLL has a high risk of various complications. ADF is reported to be effective for cervical OPLL, especially for massive OPLL. However, few studies have focused on the surgical complications of ADF.
METHODS
We prospectively included 102 patients undergoing ADF for severe cervical OPLL with average canal occupying ratio of 49.8%. We evaluated systemic and local complications, neurological complications, and risk factors related to the postoperative complications.
RESULTS
Frequently observed complications included graft/ implant complications (18.6%), neurological complications (11.8%), and cerebrospinal fluid leak (11.8%). Motor palsy involving only the upper extremity was found in nine patients (8.8%), and other motor palsies involving the lower extremities were found in three patients (2.9%). None of the preoperative factors were significantly associated with the occurrence of neurological palsies, whereas the number of operated levels was a significant factor related to the postoperative graft/implant complications (P = 0.003; odds ratio, 2.112). The incidence of graft/implant complications and related reoperation increased as the number of operated levels increased (especially four levels or more). Most motor palsies were observed immediately after surgery. Of the motor palsies in the bilateral upper extremities and palsies involving the lower extremities, 85.7% showed good recovery, whereas only 40% of unilateral upper extremity motor palsies showed good recovery during the follow-up period.
CONCLUSION
In ADF for cervical OPLL, the number of operated levels was a significant factor related to the postoperative complication. Specifically, the incidence of graft/implant complications and reoperation rate increased in ADF with four or more levels.Level of Evidence: 3.