MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00007632-199909010-00004

Медицинская библиотека · Spine · 1999

Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures.

Tohmeh A G, Mathis J M, Fenton D C, Levine A M, Belkoff S M

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Cadaveric study on the biomechanics of osteoporotic vertebral bodies augmented and not augmented with polymethylmethacrylate cement.

OBJECTIVES

To determine the strength and stiffness of osteoporotic vertebral bodies subjected to compression fractures and 1) not augmented, 2) augmented with unipedicular injection of cement, or 3) augmented with bipedicular injection of cement.

SUMMARY OF BACKGROUND DATA: Percutaneous vertebroplasty is a relatively new method of managing osteoporotic compression fractures, but it lacks biomechanical confirmation.

METHODS

Fresh vertebral bodies (L2-L5) were harvested from 10 osteoporotic spines (T scores range, -3.7 to -8.8) and compressed in a materials testing machine to determine intact strength and stiffness. They were then repaired using a transpedicular injection of cement (unipedicular or bipedicular), or they were unaugmented and recrushed.

RESULTS

Results suggest that unipedicular and bipedicular cement injection restored vertebral body stiffness to intact values, whereas unaugmented vertebral bodies were significantly more compliant than either injected or intact vertebral bodies. Vertebral bodies injected with cement (both bipedicular and unipedicular) were significantly stronger than the intact vertebral bodies, whereas unaugmented vertebral bodies were significantly weaker. There was no significant difference in loss in vertebral body height between any of the augmentation groups.

CONCLUSIONS

This study suggests that unipedicular and bipedicular injection of cement, as used during percutaneous vertebroplasty, increases acute strength and restores stiffness of vertebral bodies with compression fractures.

Для цитирования: Tohmeh A G, Mathis J M, Fenton D C, Levine A M, Belkoff S M. Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures.. Spine. 1999. DOI: 10.1097/00007632-199909010-00004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.