MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0000000000002977

Медицинская библиотека · Journal of orthopaedic trauma · 2025

Pin Site-Related Outcomes After Temporary Staging External Fixator Pin Placement Using the Self-Drilling Pin Insertion Technique.

Moon Tyler J, Moyal Andrew J, Smith Kira L, Fanaeian Elika, Suponcic Michael B, Weatherford Brian, Sontich John K, Napora Joshua K, Ochenjele George

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To report on pin-related complications in patients who underwent temporary staging external fixation using a self-drilling pin insertion technique.

DESIGN

Retrospective cohort study.

SETTING

Single tertiary referral level 1 trauma center.

PATIENT SELECTION CRITERIA: Adult patients were included who underwent temporary spanning external fixation of the lower extremity (AO/OTA 32, 33, 41, 42, 43, 44, 81, 82, 83, 84, and 85 fractures) using self-drilling and self-tapping pins placed using the self-drilling technique (Stryker Hoffman External Fixation System, Kalamazoo, MI) between August 1, 2015, and December 31, 2022, with a minimum follow-up of 90 days. The self-drilling technique included use of a soft tissue sleeve for pin protection in the femur and tibia, release of the tourniquet if inflated, and full speed insertion with the final turns completed by hand. Irrigation of the pin-bone interface was not typically used.

OUTCOME MEASURES AND COMPARISONS: Outcome measures included pin site infection, pin loosening, loss of reduction in the external fixator, and deep infection of the primary surgical site.

RESULTS

Two hundred sixty-five patients were included with a mean follow-up of 556 days. The mean age was 50 years (range 18-86 years). One hundred fifty-five patients (59%) were male. One thousand one hundred fifty-four total pins were placed: 289 (25%) in the femur (1 metaphyseal), 527 (46%) in the tibia (12 metaphyseal), 161 (14%) transfixion pins in the calcaneus, and 171 (15%) in the midfoot/forefoot. Seven patients (2.6%) developed a pin site infection. The infection rate for the total number of pins placed was 7 of 1154 (0.6%). One patient sustained a loss of reduction in the external fixator, and 3 pins were noted to be loose at the time of definitive fixation (2 in the tibial diaphysis and 1 in the first metatarsal shaft). In total, 35 of 265 patients (13.2%) developed deep fracture-related infection or septic nonunion in the postoperative period, none of which were associated with prior pin site infection.

CONCLUSIONS

The self-drilling technique for temporary external fixator pin insertion in this study demonstrated low rates of pin site infection, pin loosening, and loss of reduction.

LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Moon Tyler J, Moyal Andrew J, Smith Kira L, Fanaeian Elika, Suponcic Michael B, Weatherford Brian, Sontich John K, Napora Joshua K, Ochenjele George. Pin Site-Related Outcomes After Temporary Staging External Fixator Pin Placement Using the Self-Drilling Pin Insertion Technique.. Journal of orthopaedic trauma. 2025. DOI: 10.1097/bot.0000000000002977.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.