MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vsu.70015

Медицинская библиотека · Veterinary surgery : VS · 2025

Comparison of arthroscopy- and fluoroscopy-assisted minimally invasive approaches for acetabular fracture repair in dogs: An ex vivo study.

Huels Nikolaus Hubertus, Siedenburg Johannes

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To describe and compare arthroscopy-assisted (AA) with fluoroscopy-assisted (FA) minimally invasive plate osteosynthesis (MIPO) for simple transverse acetabular fractures.

STUDY

DESIGN

Ex vivo cadaveric study.

SAMPLE POPULATION: A total of 10 canine cadavers (>20 kg) without coxofemoral joint disease.

METHODS

Pelvic computed tomography (CT) images were mirrored and three-dimensional (3D) printed to create models for precontouring 2.7-mm locking compression plates (LCP). Acetabula were randomly assigned to AA or FA MIPO groups and pelvis were prepared for stabilization by standardized osteotomies of the pubic, ischial and acetabular bones. In the AA group, fracture reduction was arthroscopically confirmed, and precontoured plates were applied via small approaches to the ilium and ischium. In the FA group, reduction was guided fluoroscopically. Surgical time, incision length, procedural complications, and feasibility were recorded. Postprocedural CT scans measured fracture gap, step formation, medio-lateral displacement and pelvic angulation. Necropsy assessed iatrogenic injuries.

RESULTS

MIPO was successful for all 20 acetabula. Mean procedure time and incision length were not significantly different between groups. Mean fracture gaps and step defects were <1 mm in both groups. Medio-lateral displacement exceeded 1 mm in the FA group (median 1.08 mm) compared to 0.74 mm in the AA group. Low coronal angles (<5°) were consistent across procedures. Sciatic nerve injury occurred in one case per group. Minor superficial cartilage damage was common.

CONCLUSION

Arthroscopy-assisted MIPO was feasible for simple acetabular fractures, resulting in anatomic (6/10) or near-anatomic (4/10) reductions.

CLINICAL SIGNIFICANCE: Further studies and clinical experience are necessary before recommending AA as an alternative for open approaches.

Для цитирования: Huels Nikolaus Hubertus, Siedenburg Johannes. Comparison of arthroscopy- and fluoroscopy-assisted minimally invasive approaches for acetabular fracture repair in dogs: An ex vivo study.. Veterinary surgery : VS. 2025. DOI: 10.1111/vsu.70015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.