BACKGROUND

The purpose of this study was to evaluate the alpha defensin qualitative detection (ADLF) sensitivity and specificity as compared with 3 standard classifications in the diagnostic management of chronic prosthetic joint infections.

MATERIALS AND

METHODS

A multicenter cohort of 136 patients with a painful arthroplasty was classified into either infected or noninfected according to the Musculoskeletal Infection Society (MSIS) score, Infectious Diseases Society of America (IDSA) score, European Bone and Joint Infection Society (EBJIS) score. The sensitivity and specificity of the ADLF test were calculated for each score. Spearman's correlations between all scores were then analyzed, and multiple logistic regression was applied to identify independent variables strongly connected to the prosthetic joint infection probability.

RESULTS

The EBJIS score was positive in 68 patients, IDSA score in 50 patients, MSIS score in 41 patients, and ADLF in 40 patients. The ADLF sensitivity was 87.8% compared with MSIS, 70% compared with IDSA, and 55.8% compared with EBJIS. The ADLF specificity was in the range of 94%-97%. A good correlation was observed between synovial fluid cultures and ADLF (r = 0.73). Low to excellent correlations were recorded between ADLF and the EBJIS (r = 0.58), IDSA (r = 0.68), and MSIS (r = 0.84) scores. The synovial fluid's white blood cell count was proven to be the biological test that most influenced the probability of a positive culture (P value: .005).

DISCUSSION: The ADLF sensitivity was variable, whereas its specificity was excellent. The EBJIS score results significantly differed from those obtained via cultures, which possibly explains the ADLF low sensitivity compared with that of the EBJIS score.

Для цитирования: Huard Maxime, Detrembleur Christine, Poilvache Hervé, Pastor Y Geels Ines, Van Cauter Maïte, Driesen Ronald, Yombi Jean-Cyr, Neyt Jeroen, Cornu Olivier. Alpha Defensin: A Diagnostic Accuracy Depending on the Infection Definition Used.. The Journal of arthroplasty. 2019. DOI: 10.1016/j.arth.2019.12.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.