MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.xrrt.2024.05.002

Медицинская библиотека · JSES reviews, reports, and techniques · 2024

Can magnetic resonance imaging distinguish clinical stages of frozen shoulder? A state-of-the-art review.

Tamai Kazuya, Hamada Junichiro, Nagase Yuichi, Morishige Masahiko, Naito Masashi, Asai Hideaki, Tanaka Sakae

СтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

Frozen shoulder (FS) is a common disorder causing shoulder pain and limited motion. Magnetic resonance imaging (MRI) is expected to help diagnose FS and realize the disease stage if stage-specific features are present. We aimed to survey stage-related MRI findings of FS in the literature.

METHODS

MEDLINE, SCOPUS, and Google Scholar databases were searched with search terms "frozen shoulder" or "adhesive capsulitis" combined with "magnetic resonance imaging." Studies that discussed MRI findings in relation to FS stages were retrieved. The course of FS was divided into stages 1 to 4 according to Hannafin and Chiaia.

RESULTS

Two of the noncontrast-enhanced MRI findings were stage-related. T2 signal hyperintensity of the joint capsule was more frequent in stages 1 and 2. The axillary capsule thickness was greater in stages 1 and 2. However, these findings were also seen in the later stages to a lesser degree. Effusion around the long head of biceps, subcoracoid fat obliteration, and coracohumeral ligament thickening were common in FS but their relation to the stages was not evident. Signal enhancement on contrast-enhanced MRI was not consistently linked to stages.

CONCLUSION

T2 signal hyperintensity and axillary capsule thickening are characteristic of the early stages of FS, although MRI alone cannot completely define the disease stage.

Для цитирования: Tamai Kazuya, Hamada Junichiro, Nagase Yuichi, Morishige Masahiko, Naito Masashi, Asai Hideaki, Tanaka Sakae. Can magnetic resonance imaging distinguish clinical stages of frozen shoulder? A state-of-the-art review.. JSES reviews, reports, and techniques. 2024. DOI: 10.1016/j.xrrt.2024.05.002.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.