Аннотация

PURPOSE: The current literature on clinical appearance after surgery for high-grade spondylolisthesis is inconclusive. The few long-term comparative studies on surgical reduction versus in situ fusion report contradictory findings concerning appearance-related issues. The purpose of the current study was to evaluate and quantify clinical appearance three decades after in situ fusion for high-grade isthmic spondylolisthesis.

METHODS

The Scoliosis Research Society (SRS)-22r questionnaire, digital photographs and standing lateral radiographs were used to evaluate clinical appearance for 22 patients three decades after in situ fusion for high-grade spondylolisthesis. The appearance was assessed by two spine surgeons, by the patient themselves, and by quantification of cosmesis relevant radiographic variables including pelvic parameters and sagittal balance.

RESULTS

The surgeon inter- and intraobserver reliability of the photographic evaluation of the trunk deformity was at most moderate (Cohen's kappa 0.5). Correlation analysis revealed at most medium correlation between radiographic outcome and self-rated (SRS-22r) self-image (Spearman's rank correlation coefficient 0.3). The agreement between patient and surgeon-rated trunk appearance was poor (Cohen's kappa 0.2).

CONCLUSIONS

Photographic evaluation of the trunk deformity in high-grade spondylolisthesis is unreliable. There were only weak correlations between patient self-assessed trunk appearance and radiographic parameters. The results reflect the pronounced subjectivity of cosmesis, and that the trunk deformity in high-grade spondylolisthesis is not easily observed.

LEVEL OF EVIDENCE: IV.

Для цитирования: Joelson Anders, Danielson Barbro I, Hedlund Rune, Wretenberg Per, Frennered Karin. Clinical appearance and reliability in visual assessment after in situ fusion for high-grade isthmic spondylolisthesis.. Spine deformity. 2020. DOI: 10.1007/s43390-020-00208-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.