MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0117122

Медицинская библиотека · PloS one · 2015

Bony healing of unstable thoracolumbar burst fractures in the elderly using percutaneously applied titanium mesh cages and a transpedicular fixation system with expandable screws.

Eschler Anica, Ender Stephan Albrecht, Schiml Katharina, Mittlmeier Thomas, Gradl Georg

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

There is a high incidence of vertebral burst fractures following low velocity trauma in the elderly. Treatment of unstable vertebral burst fractures using the same principles like in stable vertebral burst fractures may show less favourable results in terms of fracture reduction, maintenance of reduction and cement leakage. In order to address these shortcomings this study introduces cementless fixation of unstable vertebral burst fractures using internal fixators and expandable intravertebral titanium mesh cages in a one-stage procedure via minimum-invasive techniques.

MATERIAL AND

METHODS

A total of 16 consecutive patients (median age 76 years, range 58-94) with unstable thoracolumbar burst fractures and concomitant osteoporosis were treated by an internal fixator inserted via minimum invasive technique one level above and below the fractured vertebra. Fracture reduction was achieved and maintained by transpedicular placement of two titanium mesh cages into the fractured vertebral body during the same procedure. Intra- and postoperative safety of the procedure as well as analysis of reduction quality was analysed by 3D C-arm imaging or CT, respectively. Clinical and radiographic follow-up averaged 10.4 months (range 4.5-24.5).

RESULTS

Stabilization of the collapsed vertebral body was achieved in all 16 cases without any intraoperative complication. Surgical time averaged 102 ± 6.6 minutes (71-194). The postoperative kyphotic angle (KA) and Cobb angle revealed significant improvements (KA 13.7° to 7.4°, p < 0.001; Cobb 9.6° to 6.0°, p < 0.002) with partial loss of reduction at final follow-up (KA 8.3°, Cobb 8.7°). VAS (Visual Analogue Scale) improved from 7.6 to 2.6 (p < 0.001). Adjacent fractures were not observed. One minor (malposition of pedicle screw) complication was encountered.

CONCLUSION

Cementless fixation of osteoporotic burst fractures revealed substantial pain relief, adequate maintenance of reduction and a low complication rate. Bony healing after unstable osteoporotic burst fractures is possible.

TRIAL REGISTRATION: www.germanctr.de DRKS00005657.

Для цитирования: Eschler Anica, Ender Stephan Albrecht, Schiml Katharina, Mittlmeier Thomas, Gradl Georg. Bony healing of unstable thoracolumbar burst fractures in the elderly using percutaneously applied titanium mesh cages and a transpedicular fixation system with expandable screws.. PloS one. 2015. DOI: 10.1371/journal.pone.0117122.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.