STUDY

DESIGN

Retrospective analysis of operative data from cadaveric cervical spines.

OBJECTIVE

To evaluate the accuracy of neuronavigation compared with laminotomy with direct visualization (DV) of the pedicle for placement of subaxial pedicle screws.

SUMMARY OF BACKGROUND DATA: Subaxial pedicle screws provide superior fixation compared with other posterior cervical fixation strategies. However, high accuracy is required for safe placement, given the proximity of critical neurovascular structures. Computed tomography (CT)-based neuronavigation has increased in popularity for placement of spinal implants, including subaxial pedicle screws. However, the accuracy of the technique for this application has not been extensively evaluated.

METHODS

Six fresh-frozen cadaveric spines (occiput to T2) were prepared. Pedicle screws were placed from C3 to C7 on either side using either the DV or neuronavigation technique (alternating sides between specimens). Pedicles with diameters <4 mm were excluded. For the DV technique, a hemilaminotomy was performed for DV of pedicle borders and to determine appropriate screw medialization and trajectory. Neuronavigation screws were placed using CT-based navigation with a reference frame mounted on the C2 spinous process. Screw position was evaluated using postoperative CT, and breaches were classified using the Neo classification.

RESULTS

Fifty pedicle screws were placed at 25 levels in 6 cadaveric spines; 25 screws each were placed using neuronavigation or DV. No significant difference in accuracy was found between the 2 techniques. Three (12%) breaches occurred in the DV group, and 9 (36%) breaches occurred in the neuronavigation group (P=0.10). The breaches were evenly distributed across all levels. There were no high-grade breaches with DV and only 1 (4.0%) with neuronavigation (P>0.99). Average pedicle cortical and medullary bone widths were higher for levels with no breach (P=0.009 and P=0.02, respectively).

CONCLUSIONS

High accuracy can be achieved with both neuronavigation and DV for placement of subaxial cervical pedicle screws in cadavers.

Для цитирования: Farber S Harrison, Godzik Jakub, Hlubek Randall J, Zhou James J, Walker Corey T, Kakarla U Kumar, Uribe Juan S, Turner Jay D. Accuracy of Subaxial Cervical Pedicle Screw Placement Using Direct Visualization Versus Computed Tomography-Based Navigation.. Clinical spine surgery. 2022. DOI: 10.1097/bsd.0000000000001141.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.