Медицинская библиотека · Small (Weinheim an der Bergstrasse, Germany) · 2025

Deep Learning-Enhanced Chemiluminescence Vertical Flow Assay for High-Sensitivity Cardiac Troponin I Testing.

Han Gyeo-Re, Goncharov Artem, Eryilmaz Merve, Ye Shun, Joung Hyou-Arm, Ghosh Rajesh, Ngo Emily, Tomoeda Aoi, Lee Yena, Ngo Kevin, Melton Elizabeth, Garner Omai B, Di Carlo Dino, Ozcan Aydogan

СтатьяПоддержка правительства СШАПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Democratizing biomarker testing at the point-of-care requires innovations that match laboratory-grade sensitivity and precision in an accessible format. Here, high-sensitivity detection of cardiac troponin I (cTnI) is demonstrated through innovations in chemiluminescence-based sensing, imaging, and deep learning-driven analysis. This chemiluminescence vertical flow assay (CL-VFA) enables rapid, low-cost, and precise quantification of cTnI, a key cardiac protein for assessing heart muscle damage and myocardial infarction. The CL-VFA integrates a user-friendly chemiluminescent paper-based sensor, a polymerized enzyme-based conjugate, a portable high-performance CL reader, and a neural network-based cTnI concentration inference algorithm. The CL-VFA measures cTnI over a broad dynamic range covering six orders of magnitude and operates with 50 µL of serum per test, delivering results in 25 min. This system achieves a detection limit of 0.16 pg mL-1 with an average coefficient of variation under 15%, surpassing traditional benchtop analyzers in sensitivity by an order of magnitude. In blinded validation, the computational CL-VFA accurately measures cTnI concentrations in patient samples, demonstrating a robust correlation against a clinical-grade FDA-cleared analyzer. These results highlight the potential of CL-VFA as a robust diagnostic tool for accessible, rapid cardiac biomarker testing that meets the needs of diverse healthcare settings, from emergency care to underserved regions.

Для цитирования: Han Gyeo-Re, Goncharov Artem, Eryilmaz Merve, Ye Shun, Joung Hyou-Arm, Ghosh Rajesh, Ngo Emily, Tomoeda Aoi, Lee Yena, Ngo Kevin, Melton Elizabeth, Garner Omai B, Di Carlo Dino, Ozcan Aydogan. Deep Learning-Enhanced Chemiluminescence Vertical Flow Assay for High-Sensitivity Cardiac Troponin I Testing.. Small (Weinheim an der Bergstrasse, Germany). 2025. DOI: 10.1002/smll.202411585.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.