MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1063/1.5007081

Медицинская библиотека · Biomicrofluidics · 2017

Rapid identification of pathogens responsible for necrotizing fasciitis on an integrated microfluidic system.

Yu Ju-Ching, Hsieh Pang-Hsin, Tsai Hsing-Wen, Chang Wen-Hsin, Liu Ting-Hang, Lee Mel S, Peng Kuo-Ti, Huang Kuo-Chin, Lee Gwo-Bin

СтатьяПеревод в очереди

Аннотация

Necrotic fasciitis (NF) is a particularly aggressive and serious infection of the fascia that can penetrate into the musculature and internal organs, resulting in death if not treated promptly. In this work, an integrated microfluidic system composed of micropumps, microvalves, and micromixers was used to automate the detection of pathogens associated with NF. The entire molecular diagnostic process, including bacteria isolation, lysis, nucleic acid amplification and optical detection steps, was enacted on this developed system. Mannose binding lectin coated magnetic beads were first used as probes to isolate all bacteria in a sample. In this work, polymerase chain reaction assays featuring primers specific to genes from each of four NF-causing bacteria (Vibrio vulnificus, Aeromonas hydrophila, and methicillin-sensitive and resistant Staphylococcus aureus) were used to rapidly and exclusively verify the presence of the respective bacterial strains, and the limits of detection were experimentally found to be 11, 1960, 14, and 11 400 colony forming units/reaction, respectively; all values reflect improvement over ones reported in literature. This integrated microfluidic chip may then be valuable in expediting diagnosis and optimizing treatment options for those with NF; such diagnostic improvements could ideally diminish the need for amputation and even reduce the morality rate associated with this life-threatening illness.

Для цитирования: Yu Ju-Ching, Hsieh Pang-Hsin, Tsai Hsing-Wen, Chang Wen-Hsin, Liu Ting-Hang, Lee Mel S, Peng Kuo-Ti, Huang Kuo-Chin, Lee Gwo-Bin. Rapid identification of pathogens responsible for necrotizing fasciitis on an integrated microfluidic system.. Biomicrofluidics. 2017. DOI: 10.1063/1.5007081.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.