Аннотация

OBJECTIVES

Conventional imaging techniques are routinely used in the diagnostic work-up of patients with suspected osteomyelitis or orthopaedic implant-associated infections. Hybrid nuclear medicine imaging techniques are a suitable alternative to routine imaging modalities as they provide anatomical and functional information within one procedure. Our study investigated the performance of anti-granulocyte SPECT/CT using 99mTc-labelled monoclonal antibodies in the diagnosis of osteomyelitis and orthopaedic implant-associated infections.

METHODS

In this retrospective analysis, we included patients with 99mTc-antigranulocyte SPECT/CT acquired in the context of a suspected bone and joint infection. All patients underwent routine diagnostics and/or had a clinical follow-up of at least 12months.

RESULTS

26 episodes were included. Fifteen exams were performed for suspected osteomyelitis, and 11 for suspected orthopaedic implant-associated infection. SPECT/CT was ordered most often if standard diagnostic tests or conventional imaging modalities remained inconclusive. The overall sensitivity and specificity for the diagnosis of an infection were 77.8% and 94.1%, respectively. The positive predictive value was 87.5% and the negative predictive value 88.9%. Diagnostic accuracy was 88.5%.

CONCLUSIONS

99mTc-antigranulocyte SPECT/CT imaging has a high accuracy in the diagnosis of osteomyelitis and orthopaedic implant-associated infections and is a suitable non-invasive diagnostic tool if standard diagnostic examinations are inconclusive or not applicable.

Для цитирования: Plate A, Weichselbaumer V, Schüpbach R, Fucentese S F, Berli M, Hüllner M, Achermann Y. Diagnostic accuracy of 99mTc-antigranulocyte SPECT/CT in patients with osteomyelitis and orthopaedic device-related infections: A retrospective analysis.. International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases. 2019. DOI: 10.1016/j.ijid.2019.11.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.