MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2020.04.024

Медицинская библиотека · The Journal of arthroplasty · 2020

Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty.

Hannon Charles P, Cotter Eric J, Cooper H John, Deirmengian Carl A, Rodriguez Jose A, Urban Robert M, Paprosky Wayne G, Jacobs Joshua J

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Mechanically assisted crevice corrosion (MACC) at modular junctions can cause a spectrum of adverse local tissue reactions (ALTRs) in patients who have undergone total hip arthroplasty (THA). The purpose of this study is to describe the presentation, treatments, and related complications of a cohort of patients presenting with late instability following metal-on-polyethylene THA due to underlying MACC and ALTR.

METHODS

This multicenter retrospective case series presents 17 patients (12 women, mean age 62.6, range 42-73) presenting with late instability secondary to ALTR and MACC. All patients had a metal (Cobalt Chrome)-on-polyethylene bearing surface. Patients experienced a mean 2.7 dislocations (range 1-6) at mean 4.3 years (range 0.4-17.0) following their index surgery. Serum metal levels (n = 12) demonstrated a greater elevation of cobalt (mean 6.9, range 0.13-20.88 ng/mL) than chromium (mean 1.9, range 0.13-3.23 ng/mL).

RESULTS

Patients were revised for instability at a mean of 6.8 years (range 2.1-19.4) following their index surgery. ALTR was encountered in every case and the modular head-neck junction demonstrated visible corrosion. An exchange of the CoCr head to a ceramic head with a titanium sleeve and placement of a constrained liner was performed for a majority of patients (n = 15, 88.2%). Five patients (29.4%) had complications postoperatively including peroneal palsy (n = 2), periprosthetic joint infection (n = 2), and ALTR recurrence (n = 1).

CONCLUSION

Recurrent instability in the setting of otherwise well-positioned THA components and without another obvious cause should raise concern for ALTR as a potential underlying etiology.

Для цитирования: Hannon Charles P, Cotter Eric J, Cooper H John, Deirmengian Carl A, Rodriguez Jose A, Urban Robert M, Paprosky Wayne G, Jacobs Joshua J. Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty.. The Journal of arthroplasty. 2020. DOI: 10.1016/j.arth.2020.04.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.