DOI 10.1038/s41598-019-52051-6

Медицинская библиотека · Scientific reports · 2019

Development of a multiplex and sensitive lateral flow immunoassay for the diagnosis of periprosthetic joint infection.

Tsai Tsung-Ting, Huang Tse-Hao, Ho Natalie Yi-Ju, Chen Yu-Pei, Chen Chung-An, Chen Chien-Fu

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The diagnosis of periprosthetic joint infection (PJI) remains a challenge. However, recent studies showed that synovial fluid biomarkers have demonstrated greater diagnostic accuracy than the currently used PJI diagnostic tests. In many diagnostic tests, combining several biomarkers into panels is critical for improving diagnostic efficiency, enhancing the diagnostic precision for specific diseases, and reducing cost. In this study, we prove that combining alpha-defensin and C-reactive protein (CRP) as biomarkers possesses the potential to provide accurate PJI diagnosis. To further verify the result, we developed a multi-target lateral flow immunoassay strip (msLFIA) with staking pad design to obtain on-site rapid response for clinical diagnosis of PJI. A total of 10 synovial fluid samples were tested using the msLFIA, and the results showed that the combined measurements of synovial fluid alpha-defensin and CRP levels were consistent with those obtained from a commercial enzyme-linked immunosorbent assay kit. In addition, we developed a multi-target lateral flow immunoassay strip (msLFIA) with staking pad design to obtain on-site rapid response for clinical diagnosis of PJI, which the multi-target design is used to increase specificity and the stacking pad design is to enhance detection sensitivity. As a result, the turnaround time of the highly sensitive test can be limited from several hours to 20 min. We expect that the developed msLFIA possesses the potential for routine monitoring of PJI as a convenient, low-cost, rapid and easy to use detection device for PJI.

Для цитирования: Tsai Tsung-Ting, Huang Tse-Hao, Ho Natalie Yi-Ju, Chen Yu-Pei, Chen Chung-An, Chen Chien-Fu. Development of a multiplex and sensitive lateral flow immunoassay for the diagnosis of periprosthetic joint infection.. Scientific reports. 2019. DOI: 10.1038/s41598-019-52051-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.