MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fsurg.2025.1473038

Медицинская библиотека · Frontiers in surgery · 2025

Poor radiological outcomes and associated factors among tibial shaft fracture patients treated with intramedullary nail fixation at Addis Ababa Burn, Emergency and Trauma Hospital, Ethiopia.

Shugie Yohannes, Kebede Samuel, Adugna Fanna, Demissie Dereje Bayissa, Desta Tilahun

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Tibial shaft fractures account for the majority of operatively treated long bone fractures and have the greatest prevalence of open wounds. For both open and closed injuries, intramedullary fixation has become the standard of therapy. At Addis Ababa Burn, Emergency, and Trauma (AaBET) Hospital, the rates of poor radiological outcomes for tibial shaft fractures treated with intramedullary fixation are unknown.

METHODS

A retrospective health facility-based cross-sectional study design was conducted among patients with tibial shaft fractures treated with intramedullary nails at AaBET Hospital. Data were collected by reviewing medical records and x-rays. The study was conducted on a sample size of 160 using a simple random sampling technique. Descriptive statistics such as frequency and percentage were used to summarize the results. Binary logistic regression was used to describe the associations between variables. A P-value < 0.05 was considered statistically significant.

RESULTS

This study included 122 (76.3%) men and 38 (23.8%) women with a mean age of 36.3 ± 13.9. The magnitude of poor radiological outcomes among the tibial shaft fracture patients treated with intramedullary nail fixation was 23.1%, with factors including include the presence of medical comorbidity [adjusted odd ratio (AOR) (95% confidence interval, CI): 16.5 (2.524-108.69)], having diabetes mellitus [AOR (95% CI): 3.85 (1.07-14.08)], Gustilo-Anderson type III (GA III) open fractures [AOR (95% CI): 17.4 (3.11-97.72)], and post-operative infection [AOR (95% CI): 13.9 (5.8-33.16)] identified as being significantly associated with poor radiological outcomes.

CONCLUSION

The magnitude of poor radiological outcomes in this study is comparable to other similar studies. The study found that factors including Gustilo-Anderson type III open fractures, diabetes mellitus, and post-operative infections increase the odds of poor radiological outcomes in patients with tibial shaft fractures after intramedullary nailing. Therefore, surgeons should improve their assessment and evaluation of patients with infection signs and use negative wound pressure for GA III fractures.

Для цитирования: Shugie Yohannes, Kebede Samuel, Adugna Fanna, Demissie Dereje Bayissa, Desta Tilahun. Poor radiological outcomes and associated factors among tibial shaft fracture patients treated with intramedullary nail fixation at Addis Ababa Burn, Emergency and Trauma Hospital, Ethiopia.. Frontiers in surgery. 2025. DOI: 10.3389/fsurg.2025.1473038.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.