Femoral Neck Fracture Fixation with a Medial Buttress Plate That Led to Impingement with Hip Flexion: A Case Report.

Marchand Lucas S, Karns Michael, Higgins Thomas F, Aoki Stephen K

Клинический случайСтатьяПеревод в очереди

Аннотация

CASE: A 47-year-old man with an isolated femoral neck fracture was treated with open reduction and internal fixation with a medial femoral neck buttress plate and a dynamic hip screw. Union was achieved without osteonecrosis of the femoral head. However, hip arthroscopy that was performed for persistent hip pain following the fracture union revealed an intra-articular impingement of the buttress plate and a substantial anterior acetabular chondral injury.

CONCLUSIONS

To our knowledge, this is the first reported complication associated with the application of a medial buttress plate for a femoral neck fracture. This case report may help surgeons who employ this technique to avoid a similar complication.

Для цитирования: Marchand Lucas S, Karns Michael, Higgins Thomas F, Aoki Stephen K. Femoral Neck Fracture Fixation with a Medial Buttress Plate That Led to Impingement with Hip Flexion: A Case Report.. JBJS case connector. 2019. DOI: 10.2106/jbjs.cc.18.00135.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.