Isolated tibial insert exchange in revision total knee arthroplasty : reliable and durable for wear; less so for instability, insert fracture/dissociation, or stiffness.

Tetreault Matthew W, Hines Jeremy T, Berry Daniel J, Pagnano Mark W, Trousdale Robert T, Abdel Matthew P

СтатьяПеревод в очереди

Аннотация

AIMS: This study aimed to determine outcomes of isolated tibial insert exchange (ITIE) during revision total knee arthroplasty (TKA).

METHODS

From 1985 to 2016, 270 ITIEs were performed at one institution for instability (55%, n = 148), polyethylene wear (39%, n = 105), insert fracture/dissociation (5%, n = 14), or stiffness (1%, n = 3). Patients with component loosening, implant malposition, infection, and extensor mechanism problems were excluded.

RESULTS

Survivorship free of any re-revision was 68% at ten years. For the indication of insert wear, survivorship free of any re-revision at ten years was 74%. Re-revisions were more frequent for index diagnoses other than wear (hazard ratio (HR) 1.9; p = 0.013), with ten-year survivorships of 69% for instability and 37% for insert fracture/dissociation. Following ITIE for wear, the most common reason for re-revision was aseptic loosening (33%, n = 7). For other indications, the most common reason for re-revision was recurrence of the original diagnosis. Mean Knee Society Scores improved from 54 (0 to 94) preoperatively to 77 (38 to 94) at ten years.

CONCLUSION

After ITIE, the risk and reasons for re-revision correlated with preoperative indications. The best results were for polyethylene wear. For other diagnoses, the re-revision rate was higher and the failure mode was most commonly recurrence of the original indication for the revision TKA. Cite this article: Bone Joint J 2021;103-B(6):1103-1110.

Для цитирования: Tetreault Matthew W, Hines Jeremy T, Berry Daniel J, Pagnano Mark W, Trousdale Robert T, Abdel Matthew P. Isolated tibial insert exchange in revision total knee arthroplasty : reliable and durable for wear; less so for instability, insert fracture/dissociation, or stiffness.. The bone & joint journal. 2021. DOI: 10.1302/0301-620x.103b6.bjj-2020-1954.r2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.