MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5312/wjo.v12.i5.310

Медицинская библиотека · World journal of orthopedics · 2021

Potential contribution of pedicle screw design to loosening rate in patients with degenerative diseases of the lumbar spine: An observational study.

Bokov Andrey, Pavlova Svetlana, Bulkin Anatoliy, Aleynik Alexandr, Mlyavykh Sergey

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The majority of published data report the results of biomechanical tests of various design pedicle screw performance. The clinical relevance and relative contribution of screw design to instrumentation stability have been insufficiently studied.

AIM: To estimate the contribution of screw design to rate of pedicle screw loosening in patients with degenerative diseases of the lumbar spine.

METHODS

This study is a prospective evaluation of 175 patients with degenerative diseases and instability of the lumbar spine segments. Participants underwent spinal instrumentation employing pedicle screws with posterior only or transforaminal interbody fusion. Follow-up was for 18 mo. Patients with signs of pedicle screw loosening on computed tomography were registered; logistic regression analysis was used to identify the factors that influenced the rate of loosening.

RESULTS

Parameters included in the analysis were screw geometry, type of thread, external and internal screw diameter and helical pitch, bone density in Hounsfield units, number of levels fused, instrumentation without anterior support, laminectomy, and unilateral and bilateral total facet joint resection. The rate of screw loosening decreased with the increment in outer diameter, decrease in core diameter and helical pitch. The rate of screw loosening correlated positively with the number of fused levels and decreasing bone density. Bilateral facet joint removal significantly favored pedicle screw loosening. The influence of other factors was insignificant.

CONCLUSION

Screw parameters had a significant impact on the loosening rate along with bone quality characteristics, the number of levels fused and the extensiveness of decompression. The significance of the influence of screw parameters was comparable to those of patient- and surgery-related factors. Pedicle screw loosening was influenced by helical pitch, inner and outer diameter, but screw geometry and thread type were insignificant factors.

Для цитирования: Bokov Andrey, Pavlova Svetlana, Bulkin Anatoliy, Aleynik Alexandr, Mlyavykh Sergey. Potential contribution of pedicle screw design to loosening rate in patients with degenerative diseases of the lumbar spine: An observational study.. World journal of orthopedics. 2021. DOI: 10.5312/wjo.v12.i5.310.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.