MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Spine · 1994

Vertebral artery location in relation to the vertebral body as determined by two-dimensional computed tomography evaluation.

Vaccaro A R, Ring D, Scuderi G, Garfin S R

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

This study analyzed the precise two-dimensional location of the vertebral artery within cervical vertebrae as determined by measurements obtained from axial computed tomographic images of the cervical spine.

OBJECTIVE

To determine the margin of safety necessary to avoid vertebral artery laceration during central decompression and lateral nerve root decompression for cervical spinal stenosis.

SUMMARY OF BACKGROUND DATA: Laceration of the vertebral artery is a rare but potentially catastrophic complication of anterior decompressive surgery of the cervical spine.

METHODS

The mean, standard deviation, and 95% confidence interval of the mean of measurements localizing the vertebral artery within the vertebral body were calculated from 50 transaxial computed tomography images of each of the second through sixth cervical vertebrae.

RESULTS

Both the mean interforaminal distance (from 25.90 +/- 1.89 mm at C3 to 29.30 +/- 2.70 mm at C6) and the average distance of the posterior border of the foramen transversarium from the ventral border of the spinal canal (from 2.16 +/- 1.18 mm at C3 to 3.53 +/- 1.56 mm at C6) increased from C3 to C6.

CONCLUSIONS

According to our measurements, the risk of vertebral artery laceration is greater at more cephalad vertebrae during lateral extension of central decompressive procedures and lateral nerve root decompression. Because of the variability of these parameters between individuals, accurate individual preoperative localization of the vertebral arteries is recommended.

Для цитирования: Vaccaro A R, Ring D, Scuderi G, Garfin S R. Vertebral artery location in relation to the vertebral body as determined by two-dimensional computed tomography evaluation.. Spine. 1994.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.