Development and Reliability of the OMERACT Thumb Base Osteoarthritis Magnetic Resonance Imaging Scoring System.

Kroon Féline P B, Conaghan Philip G, Foltz Violaine, Gandjbakhch Frédérique, Peterfy Charles, Eshed Iris, Genant Harry K, Østergaard Mikkel, Kloppenburg Margreet, Haugen Ida K

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To develop the Outcome Measures in Rheumatology (OMERACT) thumb base osteoarthritis (OA) magnetic resonance imaging (MRI) scoring system (TOMS) for the assessment of inflammatory and structural abnormalities in this hand OA subset, and test its cross-sectional reliability.

METHODS

Included features and their scaling were agreed upon by members of the OMERACT MRI Task Force using the Hand OA MRI scoring system as a template. A reliability exercise was performed in which 3 readers participated, using a preliminary atlas with examples to facilitate reading. Each reader independently scored a set of 20 MRI (coronal and axial T1- and T2-weighted fat-suppressed images, of which 5 included T1-weighted fat-suppressed post-Gadolinium images). Intra- and inter-reader reliability were assessed using ICC, percentage exact agreement (PEA), and percentage close agreement (PCA).

RESULTS

The TOMS assessed the first carpometacarpal (CMC-1) and scaphotrapeziotrapezoid (STT) joints for synovitis, subchondral bone defects (including erosions, cysts, and bone attrition), osteophytes, cartilage, and bone marrow lesions on a 0-3 scale (normal to severe). Subluxation was evaluated only in the CMC-1 joint (absent/present). Reliability of scoring for both joints was comparable. Interreader ICC were good for all features (0.77-0.99 and 0.74-0.96 for CMC-1 and STT joints, respectively). Intrareader reliability analyses gave similar results. PCA was ≥ 65% for all features. PEA was low to moderate, with better performance for subchondral bone defects, subluxation, and bone marrow lesions.

CONCLUSION

A thumb base OA MRI scoring system has been developed. The OMERACT TOMS demonstrated good intrareader and interreader reliability. Longitudinal studies are warranted to investigate reliability of change scores and responsiveness.

Для цитирования: Kroon Féline P B, Conaghan Philip G, Foltz Violaine, Gandjbakhch Frédérique, Peterfy Charles, Eshed Iris, Genant Harry K, Østergaard Mikkel, Kloppenburg Margreet, Haugen Ida K. Development and Reliability of the OMERACT Thumb Base Osteoarthritis Magnetic Resonance Imaging Scoring System.. The Journal of rheumatology. 2017. DOI: 10.3899/jrheum.161099.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.