MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2025.08.001

Медицинская библиотека · Journal of shoulder and elbow surgery · 2025

Comparison of locking plate alone and locking plate combined with 3D printed polymethylmethacrylate augmentation in treating proximal humerus fractures in elderly.

Ma Xiang-Yu, Han Tian-Yu, Zhou Da-Peng, Cui Dong, Liu Bing, Zhao Yong, Xue Hai-Peng, Yu Hai-Long, Yuan Hong

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Locking plates are widely used in open reduction internal fixation for proximal humeral fracture (PHF). However, the optimal surgical treatment of unstable, displaced PHF in elderly patients remains controversial. This study aimed to compare the radiological and clinical outcomes of surgical treatment of PHF in the elderly with locking plate (LP) alone and LP combined with 3D printed polymethylmethacrylate (PMMA) prosthesis augmentation (LP-PA).

METHODS

From May 2015 to April 2021, a total of 97 patients aged ≥60 years with acute unstable PHF who underwent osteosynthesis with either LP (46 patients) or LP-PA (51 patients) were retrospectively analyzed. For the LP-PA group, a customized proximal humeral prosthesis made of PMMA cement was intra-operatively fabricated by a three-dimensional (3D) printed prototype mold for the humeral medial support. Radiological outcomes were analyzed by measuring the value of neck-shaft angle and humeral head height. The clinical outcomes were evaluated using Constant-Murley Score, Disabilities of the Arm Shoulder and Hand (DASH) score, American Shoulder and Elbow Surgeons (ASES) score, and the shoulder range of motion. Pain was measured using a visual analog scale.

RESULTS

At the 1-year follow-up, all fractures healed radiologically and clinically. The mean changes of neck-shaft angle and humeral head height over the follow-up period were markedly smaller in the LP-PA group (3.8 ± 0.9° and 1.7 ± 0.3 mm) than those in the LP group (9.7 ± 2.1° and 3.2 ± 0.6 mm, both P < .0001). The LP-PA group also presented lower DASH score (17.1 ± 3.6), higher ASES score (89.5 ± 11.2) and better range of motion in forward elevation (142 ± 26°) and external rotation (59 ± 11°) compared to the LP group (28.9 ± 4.8 for DASH score, P < .0001; 82.3 ± 9.0 for ASES score, P < .001; 129 ± 21° for forward elevation, P = .008; and 52 ± 9° for external rotation, P = .001). There was no significant difference in overall complication rate between the 2 groups (P = .172), although the complication rate of screw perforation was higher in the LP-PA group (P = .025).

CONCLUSIONS

For PHF in elderly patients, the combination of LP fixation and PMMA prosthesis augmentation effectively improved humeral head support and reduction maintenance, providing satisfactory outcomes both radiologically and clinically. This technique also reduced the incidence of screw perforation associated with plate fixation alone, making it a reasonable option to ensure satisfactory clinical outcomes.

Для цитирования: Ma Xiang-Yu, Han Tian-Yu, Zhou Da-Peng, Cui Dong, Liu Bing, Zhao Yong, Xue Hai-Peng, Yu Hai-Long, Yuan Hong. Comparison of locking plate alone and locking plate combined with 3D printed polymethylmethacrylate augmentation in treating proximal humerus fractures in elderly.. Journal of shoulder and elbow surgery. 2025. DOI: 10.1016/j.jse.2025.08.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.