BACKGROUND

UKA has been proved to offer good results in treating patients with unicompartmental knee osteoarthritis (OA). However, there is still a controversy about the better fixation mode in UKA procedure between cemented and uncemented prosthesis. Therefore, this meta-analysis was conducted to compare clinical and radiological outcomes of cemented versus uncemented Oxford UKA.

HYPOTHESIS: The study surmised that uncemented Oxford UKA was associated with shorter operation time, higher function scores, lower revision rate and less radiolucency than cemented Oxford UKA.

METHODS

A meta-analysis to compare postoperative outcomes between cemented and uncemented Oxford UKA wsa conducted. The primary outcomes included Oxford knee score (OKS), revision rate, and incidence of radiolucency. The secondary outcomes included operation time, knee society score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), range of motion (ROM). PubMed, Embase, Web of Science, the Cochrane Library and China national knowledge infrastructure were searched until April, 2020 to identify studies for including. Relevant data were analyzed using RevMan v5.3.

RESULTS

We identified nine studies involving 901 patients meeting our inclusion criteria. No significant difference of OKS was found in both groups. Compared with cemented group, uncemented Oxford UKA group was associated with lower revision rate (95% CI: 0.90 to 3.73; OR=1.83) and less radiolucent lines (95% CI: 0.79 to 9.52; OR=2.75) after following up for at least 2years. The operation time was significantly shorter by 10.12minutes (95% CI: p<0.00001) in the uncemented group when compared against the cemented group. The KSS, WOMAC, ROM were not significantly different between two groups.

CONCLUSIONS

Uncemented Oxford UKA had lower revision rate, shorter operation time and less radiolucent lines than cemented Oxford UKA did. There is still need for more long follow-up clinical trials with high evidence level to determine which method of fixation is of preferable for Oxford UKA in the future.

LEVEL OF EVIDENCE: I.

Для цитирования: Ma Jinhui, Yan Yan, Wang Weiguo, Wang Bailiang, Yue Debo, Guo Wanshou. Lower early revision rates after uncemented Oxford Unicompartmental Knee Arthroplasty (UKA) than cemented Oxford UKA: A meta-analysis.. Orthopaedics & traumatology, surgery & research : OTSR. 2021. DOI: 10.1016/j.otsr.2021.102802.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.