MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jor.20332

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2007

Comparison of the stability of various internal fixators used in the treatment of osteochondritis dissecans--a mechanical model.

Morelli Moreno, Poitras Philippe, Grimes Valentine, Backman David, Dervin Geoffrey

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The purpose of this study was to determine what characteristics of fixation devices used in the treatment of osteochondritis dissecans (OCD) contribute to improved stability to resist shear loading. An OCD model was designed using rigid polyurethane foam. Each specimen consisted of two components, an osteochondral fragment and a corresponding defect. A total of 40 specimens were prepared and assigned to one of four groups: control (no extrinsic stabilizer); two 2-mm-diameter Kirschner wires (K-wires), 40 mm in length; one threaded washer and a 28-mm screw; and one threaded washer and a 38 mm screw. Each specimen was mounted onto an Iosipescu shear test fixture and subjected to shear loads at a pseudo-static displacement rate of 0.075 mm/s. All groups demonstrated some stability; controls were significantly less stable than all other groups. The group with the threaded washer and 38-mm screw demonstrated the greatest stability (p < 0.001), and no difference was noted between the K-wire and 28-mm screw groups. These results suggest that, in this OCD model, friction conferred some intrinsic stability to resist loads in shear. However, stability was improved with the use of long implants that compressed the fragments together.

Для цитирования: Morelli Moreno, Poitras Philippe, Grimes Valentine, Backman David, Dervin Geoffrey. Comparison of the stability of various internal fixators used in the treatment of osteochondritis dissecans--a mechanical model.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2007. DOI: 10.1002/jor.20332.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.