MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.artd.2022.08.007

Медицинская библиотека · Arthroplasty today · 2022

Minimum 2-Year Outcomes of a Novel 3D-printed Fully Porous Titanium Acetabular Shell in Revision Total Hip Arthroplasty.

Berlinberg Elyse J, Kavian J Abraham, Roof Mackenzie A, Shichman Ittai, Frykberg Brett, Lutes William B, Schnaser Erik A, Jones Stephen A, McCalden Richard W, Schwarzkopf Ran

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Fully porous acetabular shells are an appealing choice for patients with extensive acetabular defects undergoing revision total hip arthroplasty (rTHA). This study reports on the early outcomes of a novel 3-D printed fully porous titanium acetabular shell in revision acetabular reconstruction.

METHODS

A multicenter retrospective study of patients who received a fully porous titanium acetabular shell for rTHA with a minimum of 2 years of follow-up was conducted. The primary outcome was rate of acetabular revision.

RESULTS

The final study cohort comprised 68 patients with a mean age of 67.6 years (standard deviation 10.4) and body mass index of 29.5 kg/m2 (standard deviation 5.9). Ninety-four percent had a preoperative Paprosky defect grade of 2A or higher. The average follow-up duration was 3.0 years (range 2.0-5.1). Revision-free survivorship at 2 years was 81% for all causes, 88% for acetabular revisions, and 90% for acetabular revision for aseptic acetabular shell failure. Eight shells were explanted within 2 years (12%): 3 for failure of osseointegration/aseptic loosening (4%) after 15, 17, and 20 months; 3 for infection (4%) after 1, 3, and 6 months; and 2 for instability (3%). At the latest postoperative follow-up, all unrevised shells showed radiographic signs of osseointegration, and none had migrated.

CONCLUSIONS

This novel 3-D printed fully porous titanium shell in rTHA demonstrated good survivorship and osseointegration when used in complex acetabular reconstruction at a minimum of 2 years.

LEVEL OF EVIDENCE: IV, case series.

Для цитирования: Berlinberg Elyse J, Kavian J Abraham, Roof Mackenzie A, Shichman Ittai, Frykberg Brett, Lutes William B, Schnaser Erik A, Jones Stephen A, McCalden Richard W, Schwarzkopf Ran. Minimum 2-Year Outcomes of a Novel 3D-printed Fully Porous Titanium Acetabular Shell in Revision Total Hip Arthroplasty.. Arthroplasty today. 2022. DOI: 10.1016/j.artd.2022.08.007.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.