m+Medelevator.RU
← Поиск публикаций
European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025

Rigid sacropelvic fixation for lumbosacral instability following external hemipelvectomy for malignant peripheral nerve sheath tumor using CT navigation and virtual reality imaging: a case report and literature review.

СтатьяКлинический случайОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Funao Haruki, Iwata Shintaro, Narita Wataru, Mizukoshi Ryo, Ito Keitaro, Fujita Naruhito, Kawai Akira, Isogai Norihiro, Yagi Mitsuru

Аннотация

PURPOSE: To report a rare case of lumbosacral instability following a right external hemipelvectomy for malignant peripheral nerve sheath tumor (MPNST), successfully treated with rigid sacropelvic fixation using a combination of a unilateral iliac screw and an S2 alar-iliac screw.

METHODS: MPNST is a malignant soft tissue sarcoma with a high recurrence rate and poor prognosis. A 44-year-old woman was diagnosed with MPNST in the right pelvis. Despite multiple courses of chemotherapy, the tumor lesion continued to grow. A right external hemipelvectomy was performed, and histopathological analysis confirmed the diagnosis of spindle cell sarcoma consistent with MPNST. Although the tumor was radically resected, the patient developed severe low back pain due to instability at L5-S1.

RESULTS: Sacropelvic fixation was performed using a unilateral iliac screw and an S2 alar-iliac screw. Intraoperative computed tomography (CT) navigation and virtual reality (VR) images proved invaluable for preoperative planning and for identifying anatomical landmarks during the surgery. The patient had a favorable outcome, with no recurrence observed six years postoperatively.

CONCLUSION: Rigid sacropelvic fixation using a combination of a unilateral iliac screw and an S2 alar-iliac screw was successfully performed for lumbosacral instability following the external hemipelvectomy for MPNST, aided by intraoperative CT navigation and VR imaging technologies. Stable fixation was achieved, with no recurrence of MPNST.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты