DOI 10.1016/j.otsr.2019.10.028
Tantalum implants for posterior lumbar interbody fusion: A safe method at medium-term follow-up?
Аннотация
INTRODUCTION
Intervertebral implants increase stability and improve results in lumbar interbody fusion (LIF). The aim of the present study was to assess clinical and radiological results of posterior lumbar interbody fusion (PLIF) using a tantalum intervertebral implant without associated interbody bone graft.
MATERIEL AND
METHODS
A single-center retrospective study included 52 cases of single-level PLIF, using 2 tantalum intervertebral cages, without interbody bone graft: 42 for degenerative disc disease, 10 for isthmic spondylolisthesis. Minimum follow-up was 2 years. Clinical assessment used a visual analog (pain) scale (VAS), the Oswestry Disability Index (ODI) and the Roland Morris (RM) scale. Tantalum osseointegration and intersegment mobility were assessed on static and dynamic X-ray.
RESULTS
Forty-nine patients were included, with a mean 55months' follow-up (range, 25-74months). VAS, ODI and RM scores showed significant improvement at last-follow-up, at 4, 30 and 28 points respectively. There was no mechanical failure on static X-ray; all patients had less than 5° mobility on dynamic X-ray at last follow-up.
DISCUSSION: PLIF with tantalum intervertebral implant without interbody bone graft provided satisfactory clinical and radiological results at medium-term follow-up. The present findings showed reliable primary stability and osseointegration of the tantalum implant.
LEVEL OF EVIDENCE: IV.