MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.otsr.2019.10.028

Медицинская библиотека · Orthopaedics & traumatology, surgery & research : OTSR · 2020

Tantalum implants for posterior lumbar interbody fusion: A safe method at medium-term follow-up?

Lebhar Jonathan, Kriegel Pierre, Chatellier Patrick, Breton Yann, Ropars Mickael, Huten Denis

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Intervertebral implants increase stability and improve results in lumbar interbody fusion (LIF). The aim of the present study was to assess clinical and radiological results of posterior lumbar interbody fusion (PLIF) using a tantalum intervertebral implant without associated interbody bone graft.

MATERIEL AND

METHODS

A single-center retrospective study included 52 cases of single-level PLIF, using 2 tantalum intervertebral cages, without interbody bone graft: 42 for degenerative disc disease, 10 for isthmic spondylolisthesis. Minimum follow-up was 2 years. Clinical assessment used a visual analog (pain) scale (VAS), the Oswestry Disability Index (ODI) and the Roland Morris (RM) scale. Tantalum osseointegration and intersegment mobility were assessed on static and dynamic X-ray.

RESULTS

Forty-nine patients were included, with a mean 55months' follow-up (range, 25-74months). VAS, ODI and RM scores showed significant improvement at last-follow-up, at 4, 30 and 28 points respectively. There was no mechanical failure on static X-ray; all patients had less than 5° mobility on dynamic X-ray at last follow-up.

DISCUSSION: PLIF with tantalum intervertebral implant without interbody bone graft provided satisfactory clinical and radiological results at medium-term follow-up. The present findings showed reliable primary stability and osseointegration of the tantalum implant.

LEVEL OF EVIDENCE: IV.

Для цитирования: Lebhar Jonathan, Kriegel Pierre, Chatellier Patrick, Breton Yann, Ropars Mickael, Huten Denis. Tantalum implants for posterior lumbar interbody fusion: A safe method at medium-term follow-up?. Orthopaedics & traumatology, surgery & research : OTSR. 2020. DOI: 10.1016/j.otsr.2019.10.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.