Endovascular treatment of persistent sciatic artery aneurysm with the multilayer stent.
Аннотация
PURPOSE: To describe the successful management of a symptomatic persistent sciatic artery (PSA) aneurysm using the Multilayer Aneurysm Repair System (MARS).
CASE REPORT: A 50-year-old man with history of smoking, hypertension, and hypercholesterolemia suddenly developed pain in the buttock radiating to the left lower limb, mimicking sciatica. The ∼57×54-mm incomplete type PSA aneurysm was treated with two 14×80- and 14×60-mm MARS devices through a surgical left axillary artery access. There were no periprocedural complications. Thirty-day imaging documented patency of the stents and a minor reduction (∼47×55 mm) in the aneurysm, with slightly hyperdense content and no signs of perfusion. At 6 months, duplex and computed tomographic angiography showed complete thrombosis of the sac, patency of the multilayer stents, and further aneurysm shrinkage (40×37 mm).
CONCLUSION
The multilayer stent can alter the hemodynamics inside a peripheral aneurysm to promote sac thrombosis and redirect flow to collaterals originating from the sac.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.