MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ksa.12644

Медицинская библиотека · Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025

Prospective, randomised controlled trial comparing robotic arm-assisted bi-unicompartmental knee arthroplasty to total knee arthroplasty.

Farhan-Alanie Omer M, Doonan James, Rowe Philip J, Banger Matthew S, Jones Bryn G, MacLean Angus D, Blyth Mark J G

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: The objective of this study was to compare the clinical outcomes 2 years following surgery between robotic-arm assisted bi-unicompartmental knee arthroplasty (bi-UKA) compared with conventional mechanically aligned total knee arthroplasty (TKA).

METHODS

This is a single-centre, double-blinded, randomised controlled trial comparing bi-UKA and TKA. Patient-reported outcome measures (PROMs) were collected from 60 patients (27 bi-UKA and 33 TKA patients) 2 years following surgery, including Oxford Knee Score (OKS), New Knee Society Score (NKSS), Forgotten Joint Score, EQ-5D-3L, UCLA activity scale, Hospital Anxiety and Depression Scale, Pain and Stiffness Visual Analogue Scales, Satisfaction and Range of Motion. Complications were also recorded at each visit.

RESULTS

TKA and bi-UKA continue to offer comparable PROMs. The clinical NKSS demonstrated a significant difference between the two interventions, TKA 59.5 (37-65) versus bi-UKA 26.0 (22-40) (p < 0.001). There were no significant differences shown between the interventions across all time points and remaining outcome measures (OKS at 2-year follow-up; TKA-42.0 [34.0-45.5] vs. bi-UKA-41.0 [28.0-45.0]) or the proportion of participant achieving bi-phasic gait at 2 years following surgery (p = 0.429). There was no difference in complication rates following surgery at 2 years.

CONCLUSION

Robotic arm-assisted, cruciate-sparing bi-UKA and mechanically aligned TKA offer similar clinical outcomes 2 years following surgery with no difference in complication rates. Further, follow-up is required to monitor patients as they enter mid/long-term follow-up and determine whether patients will gain long-term benefits from the cruciate-sparing bi-UKA approach.

LEVEL OF EVIDENCE: Level I.

Для цитирования: Farhan-Alanie Omer M, Doonan James, Rowe Philip J, Banger Matthew S, Jones Bryn G, MacLean Angus D, Blyth Mark J G. Prospective, randomised controlled trial comparing robotic arm-assisted bi-unicompartmental knee arthroplasty to total knee arthroplasty.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2025. DOI: 10.1002/ksa.12644.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.