MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jalm/jfag093

Медицинская библиотека · The journal of applied laboratory medicine · 2026

Comparability of GFAP and UCH-L1 Measurements Using Handheld and Core Laboratory TBI Plasma Tests and Their Diagnostic Performance for Traumatic Intracranial Lesions.

Roberts Nathan B, Gherasim Carmen, Li Kexin, Xie Tian, Falk Hayley, Bapuraj Jayapalli, Demski Debra, Fung Christopher M, Haas Nathan L, Kocher Keith E, Seagly Katharine S, Medlin Richard P, Joseph Jacob, Schipper Matthew J, Chandran Raj, Marino Jaime A, McQuiston Beth, Pradhan-Bhatt Swati, Korley Frederick K

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Glial fibrillary acidic protein (GFAP) and ubiquitin carboxy-terminal hydrolase L1 (UCH-L1) are cleared by the U.S. Food and Drug Administration (FDA) to aid computed tomography (CT) decision-making in patients with traumatic brain injury (TBI). Two commercial assays, i-STAT TBI Plasma test and Alinity i TBI test, quantify these biomarkers using distinct detection technologies. Limited comparative data exist, creating uncertainty about cross-platform agreement and interchangeability of results in clinical and research applications.

METHODS

GFAP and UCH-L1 concentrations were measured twice from 829 adults who underwent brain CT within 24 h of blunt trauma, first using the Abbott i-STAT TBI Plasma test and second using the Alinity i TBI test. Agreement was assessed using percent agreement (binary outcomes), Bland-Altman plots, Passing-Bablok regression, and Pearson correlation, with and without imputed values for out-of-range results. Diagnostic accuracy for traumatic intracranial lesions (tICLs) was calculated at assay-specific cutoffs.

RESULTS

For GFAP + UCH-L1 in combination, the overall cross-platform agreement was 92.28%. GFAP and UCH-L1 showed strong cross-platform correlations with imputed (r = 0.916 and 0.916, respectively) and non-imputed data (r = 0.942 and 0.909, respectively). Both tests detected all clinically significant tICLs, with sensitivities of 100% (95% CI, 89%-100%) and negative predictive value (NPV) of 100% (95% CI, 98%-100%). Specificities were 29% (95% CI, 26%-32%) for i-STAT and 25% (95% CI, 22%-28%) for Alinity i.

CONCLUSIONS

GFAP and UCH-L1 showed strong cross-platform agreement, individually and in combination, with equivalent sensitivity for tICL, supporting clinical interchangeability of the binary positive/negative test results.

Для цитирования: Roberts Nathan B, Gherasim Carmen, Li Kexin, Xie Tian, Falk Hayley, Bapuraj Jayapalli, Demski Debra, Fung Christopher M, Haas Nathan L, Kocher Keith E, Seagly Katharine S, Medlin Richard P, Joseph Jacob, Schipper Matthew J, Chandran Raj, Marino Jaime A, McQuiston Beth, Pradhan-Bhatt Swati, Korley Frederick K. Comparability of GFAP and UCH-L1 Measurements Using Handheld and Core Laboratory TBI Plasma Tests and Their Diagnostic Performance for Traumatic Intracranial Lesions.. The journal of applied laboratory medicine. 2026. DOI: 10.1093/jalm/jfag093.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.