MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ptsp.2024.04.008

Медицинская библиотека · Physical therapy in sport : official journal of the Association of Chartered Physiotherapists in Sports Medicine · 2024

Validity of a commercially available load cell dynamometer in measuring isometric knee extension torque in patients with knee disorders.

Center John A, Willy Richard W, Elias Audrey R C, Mischke John J

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Assess the validity of hand-held dynamometry (HHD) and the Tindeq Progressor (TP) in assessing peak isometric knee extension torque and limb symmetry index (LSI) versus isokinetic dynamometer (IKD).

DESIGN

Prospective cross-sectional study.

SETTING

Laboratory.

PARTICIPANTS

31 individuals with unilateral knee disorders (21 female; 28.3 ± 11 years).

MAIN OUTCOME MEASURES: Peak isometric knee extension torque; Knee extension LSI.

RESULTS

Strong to almost perfect (p < 0.001) correlations (Cohen's Kappa k) with IKD were found for both devices for peak torque of the uninvolved limb (HHD [k = 0.84], TP [k = 0.91]) and involved limb (HHD [k = 0.93], TP [k = 0.98]). For LSI, moderate to strong (p < 0.001) correlations with IKD were found for HHD (k = 0.79) and TP (k = 0.89). Mean bias errors were equivalent for determining LSI (HHD = 0.02%; TP = 0.03%). Both HHD and TP were highly sensitive (96.2-100.0%) and specific (100.0%) at the 70% LSI threshold. TP showed higher sensitivity and specificity at the 90% LSI threshold.

CONCLUSION

HHD and TP are valid in measuring isometric knee extension torque with the reference standard IKD. TP showed superior validity in identifying LSI. TP also shows greater specificity in identifying the 90% LSI threshold.

Для цитирования: Center John A, Willy Richard W, Elias Audrey R C, Mischke John J. Validity of a commercially available load cell dynamometer in measuring isometric knee extension torque in patients with knee disorders.. Physical therapy in sport : official journal of the Association of Chartered Physiotherapists in Sports Medicine. 2024. DOI: 10.1016/j.ptsp.2024.04.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.