MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajem.2021.10.030

Медицинская библиотека · The American journal of emergency medicine · 2021

Injury characteristics and hemodynamics associated with guideline-compliant CPR in a pediatric porcine cardiac arrest model.

Salcido David D, Koller Allison C, Genbrugge Cornelia, Fink Ericka L, Berg Robert A, Menegazzi James J

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Guidelines for depth of chest compressions in pediatric cardiopulmonary resuscitation (CPR) are based on sparse evidence.

OBJECTIVE

We sought to evaluate the performance of the two most widely recommended chest compression depth levels for pediatric CPR (1.5 in. and 1/3 the anterior-posterior diameter- APd) in a controlled swine model of asphyxial cardiac arrest.

METHODS

We executed a 2-group, randomized laboratory study with an adaptive design allowing early termination for overwhelming injury or benefit. Forty mixed-breed domestic swine (mean weight = 26 kg) were sedated, anesthetized and paralyzed along with endotracheal intubation and mechanical ventilation. Asphyxial cardiac arrest was induced with fentanyl overdose. Animals were untreated for 9 min followed by mechanical CPR with a target depth of 1.5 in. or 1/3 the APd. Advanced life support drugs were administered IV after 4 min of basic resuscitation followed by defibrillation at 14 min. The primary outcomes were return of spontaneous circulation (ROSC), hemodynamics and CPR-related injury severity.

RESULTS

Enrollment in the 1/3 APd group was stopped early due to overwhelming differences in injury. Twenty-three animals were assigned to the 1.5 in. group and 15 assigned to the 1/3 APd group, per an adaptive group design. The 1/3 APd group had increased frequency of rib fracture (6.7 vs 1.7, p < 0.001) and higher proportions of several anatomic injury markers than the 1.5 in. group, including sternal fracture, hemothorax and blood in the endotracheal tube (p < 0.001). ROSC and hemodynamic measures were similar between groups.

CONCLUSION

In this pediatric model of cardiac arrest, chest compressions to 1/3APd were more harmful without a concurrent benefit for resuscitation outcomes compared to the 1.5 in. compression group.

Для цитирования: Salcido David D, Koller Allison C, Genbrugge Cornelia, Fink Ericka L, Berg Robert A, Menegazzi James J. Injury characteristics and hemodynamics associated with guideline-compliant CPR in a pediatric porcine cardiac arrest model.. The American journal of emergency medicine. 2021. DOI: 10.1016/j.ajem.2021.10.030.