INTRODUCTION

Instability accounts for 1/3 of revision total hip arthroplasty (rTHA) performed in the UK. Removal of well-fixed femoral stems in rTHA is challenging with a risk of blood loss and iatrogenic damage to the femur. The Bioball universal adaptor (BUA), a modular head neck extension adaptor, provides a mechanism for optimisation of femoral offset, leg length and femoral anteversion. This can avoid the need for femoral stem revision in selected cases.The aim of this study is to present the clinical results and rate of instability following revision with this BUA at a minimum of 2 years follow-up.

PATIENTS AND

METHODS

A review of our prospectively collected database was performed. All patients treated with the Bioball device were included. Clinical and radiologic review were performed pre- and post-surgery. Specific enquiry for instability was made. The Oxford Hip Score (OHS), EuroQol (EQ-5D) score and WOMAC scores were calculated pre-and post-operatively. Complications were recorded.

RESULTS

32 rTHA procedures were performed using the Bioball device between 2013 and 2016. 4 patients did not wish to complete post-operative questionnaires. 2 patients (2/28, 7%) complained of recurrent dislocations following their rTHA procedure. 1 patient complained of instability but no dislocation. The median pre-operative EQ-5D was 0.195 (range -0.07-0.85), OHS was 20 (range 5-43) and WOMAC was 29.8 (range 15.5-52.3). The median EQ-5D was 0.85 (range 0.59-1), OHS was 39 (range 21-48) and WOMAC was 91.1 (range 44.5-99.2) at final follow-up. There were significant improvements in the EQ-5D (p = 0.0009), OHS (p = 0.0004) and WOMAC (p = 0.0001).

CONCLUSION

The BUA is associated with significant functional improvement and relatively low dislocation rates in revision THA. It is a viable option for use in the revision setting.

Для цитирования: Dabis John, Hutt Jonathan R, Ward David, Field Richard, Mitchell Philip A, Sandiford Nemandra Amir. Clinical outcomes and dislocation rates after hip reconstruction using the Bioball system.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2019. DOI: 10.1177/1120700019858345.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.