MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2021.01.041

Медицинская библиотека · World neurosurgery · 2021

Use of Intraoperative Computed Tomography Improves Outcome of Minimally Invasive Transforaminal Lumbar Interbody Fusion: A Single-Center Retrospective Cohort Study.

Venier Alice, Croci Davide, Robert Thomas, Distefano Daniela, Presilla Stefano, Scarone Pietro

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To provide data about surgical workflow, accuracy, complications, radiation exposure, and learning curve effect in patients who underwent minimally invasive (MIS) transforaminal lumbar interbody fusion with navigation coupled with mobile intraoperative computed tomography.

METHODS

A retrospective analysis was performed of data from consecutive patients who underwent single- or double-level MIS transforaminal lumbar interbody fusion at a single institution; mobile intraoperative computed tomography combined with a navigation system was used as the sole intraoperative imaging method to place pedicular screws; decompression and interbody fusion were performed through a 22-mm tubular retractor. Clinical data, perioperative complications, accuracy of pedicular screw placement, and radiation exposure were analyzed. A learning curve effect on surgical time and accuracy was assessed.

RESULTS

A total of 408 screws in 100 patients were analyzed. In all cases, spinal navigation allowed for identification of pedicular trajectories and greatly facilitated nerve root decompression through the MIS approach. Overall accuracy according to Heary classification was 95.3%. Nineteen screws (4.7%) presented a minor lateral breach (<2 mm), not clinically significant. Surgical time, blood loss, and patient radiation exposure compared favorably with reported values from other series using three-dimensional navigation. A learning curve effect on surgical time, but not on screw accuracy, was identified.

CONCLUSIONS

MIS transforaminal lumbar interbody fusion can now be performed without any radiation exposure to the surgeon and operating room staff, with almost absolute accuracy during screw positioning and tubular decompression. A learning curve effect on surgical time, but not on overall screw accuracy, may be expected.

Для цитирования: Venier Alice, Croci Davide, Robert Thomas, Distefano Daniela, Presilla Stefano, Scarone Pietro. Use of Intraoperative Computed Tomography Improves Outcome of Minimally Invasive Transforaminal Lumbar Interbody Fusion: A Single-Center Retrospective Cohort Study.. World neurosurgery. 2021. DOI: 10.1016/j.wneu.2021.01.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.