BACKGROUND

Most implants for total knee arthroplasty (TKA) are comprised of alloys that contain nickel. Controversy exists whether metal allergies produce negative effects and affect clinical outcomes. The purpose of this study was to retrospectively review a minimum 2-year follow-up with an ion-bombarded titanium TKA implant in patients with reported metal sensitivity.

METHODS

A retrospective review of patients who underwent primary TKA with the ion-bombarded titanium Vanguard (Zimmer Biomet, Warsaw, IN) implant with 2-year minimum follow-up was performed from 2008 through 2017. The query revealed 346 patients (451 knees) with minimum 2-year follow-up. The mean age was 64.7 years, the mean body mass index was 35.1 kg/m2, and 95% of patients were women.

RESULTS

The mean follow-up was 4.6 years. The mean range of motion improved from 109° to 112° (P = .03), University of California Los Angeles activity scale from 4.1 to 5.1 (P < .001), Knee Society Clinical scores from 36 to 89 (P < .001), and Knee Society Functional scores from 48 to 73 (P < .001). There were 5 (1.1%) revisions: 2 infections (2-staged exchange), 1 tibial revision for aseptic loosening after a fall, and 2 bearing exchanges for instability. Other surgeries were open reduction internal fixation of periprosthetic fracture, 1 arthroscopic release of snapping popliteus, and 4 local wound incision and debridement (2 superficial infections and 2 nonhealing wounds). Manipulation under anesthesia was required in 27 (6%) patients.

CONCLUSIONS

These early results are encouraging for the use of alternative metal titanium alloy implants in metal-sensitive patients undergoing primary TKA. At 4.6 years of mean follow-up, patients had substantial improvement in the range of motion and clinical outcomes with a low frequency of revision.

Для цитирования: Law Jesua I, Morris Micael J, Hurst Jason M, Berend Keith R, Lombardi Adolph V, Crawford David A. Early Outcomes of an Alternative Bearing Surface in Primary Total Knee Arthroplasty in Patients with Self-reported Metal Allergy.. Arthroplasty today. 2020. DOI: 10.1016/j.artd.2020.07.021.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.