MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/ar3029

Медицинская библиотека · Arthritis research & therapy · 2010

Clinical and serological evaluation of a novel CENP-A peptide based ELISA.

Mahler Michael, Maes Liesbeth, Blockmans Daniel, Westhovens Rene, Bossuyt Xavier, Riemekasten Gabriela, Schneider Sandra, Hiepe Falk, Swart Andreas, Gürtler Irmgard, Egerer Karl, Fooke Margrit, Fritzler Marvin J

Оценочное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Anti-centromere antibodies (ACA) are useful biomarkers in the diagnosis of systemic sclerosis (SSc). ACA are found in 20 to 40% of SSc patients and, albeit with lower prevalence, in patients with other systemic autoimmune rheumatic diseases. Historically, ACA were detected by indirect immunofluorescence (IIF) on HEp-2 cells and confirmed by immunoassays using recombinant CENP-B. The objective of this study was to evaluate a novel CENP-A peptide ELISA.

METHODS

Sera collected from SSc patients (n=334) and various other diseases (n=619) and from healthy controls (n=175) were tested for anti-CENP-A antibodies by the novel CENP-A enzyme linked immunosorbent assay (ELISA). Furthermore, ACA were determined in the disease cohorts by IIF (ImmunoConcepts, Sacramento, CA, USA), CENP-B ELISA (Dr. Fooke), EliA CENP (Phadia, Freiburg, Germany) and line-immunoassay (LIA, Mikrogen, Neuried, Germany). Serological and clinical associations of anti-CENP-A with other autoantibodies were conducted in one participating centre. Inhibition experiments with either the CENP-A peptide or recombinant CENP-B were carried out to analyse the specificity of anti-CENP-A and -B antibodies.

RESULTS

The CENP-A ELISA results were in good agreement with other ACA detection methods. According to the kappa method, the qualitative agreements were: 0.73 (vs. IIF), 0.81 (vs. LIA), 0.86 (vs. CENP-B ELISA) and 0.97 (vs. EliA CENP). The quantitative comparison between CENP-A and CENP-B ELISA using 265 samples revealed a correlation value of rho=0.5 (by Spearman equation). The receiver operating characteristic analysis indicated that the discrimination between SSc patients (n=131) and various controls (n=134) was significantly better using the CENP-A as compared to CENP-B ELISA (P<0.0001). Modified Rodnan skin score was significantly lower in the CENP-A negative group compared to the positive patients (P=0.013). Inhibition experiments revealed no significant cross reactivity of anti-CENP-A and anti-CENP-B antibodies. Statistically relevant differences for gender ratio (P=0.0103), specific joint involvement (Jaccoud) (P=0.0006) and anti-phospholipid syndrome (P=0.0157) between ACA positive SLE patients and the entire SLE cohort were observed.

CONCLUSIONS

Anti-CENP-A antibodies as determined by peptide ELISA represent a sensitive, specific and independent marker for the detection of ACA and are useful biomarkers for the diagnosis of SSc. Our data suggest that anti-CENP-A antibodies are a more specific biomarker for SSc than antibodies to CENP-B. Furthers studies are required to verify these findings.

Для цитирования: Mahler Michael, Maes Liesbeth, Blockmans Daniel, Westhovens Rene, Bossuyt Xavier, Riemekasten Gabriela, Schneider Sandra, Hiepe Falk, Swart Andreas, Gürtler Irmgard, Egerer Karl, Fooke Margrit, Fritzler Marvin J. Clinical and serological evaluation of a novel CENP-A peptide based ELISA.. Arthritis research & therapy. 2010. DOI: 10.1186/ar3029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.