MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-016-4473-9

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2016

Surgical planning, manufacturing and implantation of an individualized cervical fusion titanium cage using patient-specific data.

Spetzger Uwe, Frasca Miles, König Stefan Alexander

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Most cervical fusion cages imperfectly mimic the anatomy of the intervertebral disc space. The production of individualized cages might be the next step to further improve spinal implants due to their enhanced load-bearing surface.

OBJECTIVE

To evaluate the planning, manufacturing, and implantation of an individualized cervical cage in co-operation with EIT and 3D Systems.

METHODS

A digital 3D model of the patient's cervical spine was rendered from the patients CT data. It was then possible to correct degenerative deformities by digitally repositioning the vertebrae and virtually resecting the osteophytes. The implantation of the cage can be simulated to check the accuracy of the fit. The cage is made of trabecular titanium and manufactured by Direct Metal Printing.

RESULTS

The pilot project for the implantation of the first individualized cervical cage ever, resulted in a highly accurate fit. During surgery, the cage self-located into the correct position after suspending distraction due to the implants unique end plate design. Furthermore, it was impossible to move the cage in any direction with the inserting instrument after suspending distraction for the same reason. Thus, it can be assumed that an individualized cervical implant provides excellent primary stability.

CONCLUSION

Preconditions for the manufacturing of individualized cervical fusion cages using specific patient data are given. The implantation is uncomplicated. The improved load-bearing surface will lower the rate of implant dislocation and subsidence. The production of individualized cages at a reasonable price has to be evaluated by spine surgeons and the industry.

Для цитирования: Spetzger Uwe, Frasca Miles, König Stefan Alexander. Surgical planning, manufacturing and implantation of an individualized cervical fusion titanium cage using patient-specific data.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2016. DOI: 10.1007/s00586-016-4473-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.