Point-of-care ultrasound for umbilical venous catheter placement and surveillance in neonates: practical guidance and governance.

Bhojnagarwala Bikash, Montasser Mahmoud, Banerjee Jay, Kulkarni Anay

СтатьяОбзорПеревод в очереди

Аннотация

Umbilical venous catheters (UVCs) are essential in neonatal intensive care, yet malposition and early migration are common and can cause serious hepatic or cardiac injury. We set out a structured, image-based approach to UVC placement and surveillance using point-of-care ultrasound (POCUS). We undertook a targeted narrative review of literature from 2005 to 2025, drawing on comparative studies, systematic reviews, meta-analyses, and society guidance on neonatal POCUS and vascular access. Findings were synthesised into a continuous bedside workflow covering placement, real-time correction of malposition, surveillance, and governance. POCUS directly visualises the UVC tip at the inferior vena cava-right atrial junction and detects portal, hepatic, and intracardiac malposition more reliably than radiography (reported sensitivity and specificity for cavoatrial localisation > 90% vs 60-70%). Tip migration occurs in 50-90% of neonates within the first 72 h, so a single confirmatory scan at insertion is insufficient. A three-view protocol (situs, subcostal IVC-RA, coronal/oblique) combined with a multi-probe approach reduces misclassification: the curvilinear probe maps the intrahepatic course, the linear probe confirms the tip, and the phased-array probe is reserved for cardiac views. Operator-dependent ultrasound artefact misidentification is a key clinical pitfall that requires multi-planar confirmation and explicit competency standards.

Conclusion

A three-view, multi-probe POCUS protocol improves UVC tip confirmation, allows earlier correction of malposition, and detects migration sooner than repeat radiography. Safe local adoption requires recognition of operator-dependent artefact pitfalls within a structured training and governance framework.

Для цитирования: Bhojnagarwala Bikash, Montasser Mahmoud, Banerjee Jay, Kulkarni Anay. Point-of-care ultrasound for umbilical venous catheter placement and surveillance in neonates: practical guidance and governance.. European journal of pediatrics. 2026. DOI: 10.1007/s00431-026-07392-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.