MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-018-2341-y

Медицинская библиотека · BMC musculoskeletal disorders · 2018

Reattachment of the flexor and extensor tendons at the epicondyle in elbow instability: a biomechanical comparison of techniques.

Lenich Andreas, Pfeifer Christian, Proier Philipp, Fleer Roman, Wijdicks Coen, Roth Martina, Martetschläger Frank, Pogorzelski Jonas

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Elbow dislocation represents a common injury, especially in the younger population. If treated surgically, the reattached tendons require a high amount of primary stability to allow for an early rehabilitation to avoid postoperative stiffness. The purpose of this study was to assess the biomechanical properties of a single and a double row technique for reattachment of the common extensor and common flexor muscles origin. We hypothesized that the double row technique would provide greater stability in terms of pullout forces than the single row technique.

METHODS

Twelve cadaveric specimens were randomized into two groups of fixation methods for the common extensor tendon or the common flexor tendon at the elbow (1): a single row technique using two knotted 3.0 mm suture anchors, and (2) a double row technique using an additional knotless 3.5 mm anchor. The repairs were cyclically loaded over 500 cycles at 1 Hz from 10 N to a maximum of 100 N (extensors) or 150 N (flexors), and then pulled to failure. Stiffness and maximum load at failure and mode of failure were recorded and calculated.

RESULTS

No significant differences in stiffness were observed between the two techniques for both the extensor and flexor reattachment (P = 0.701 and P = 0.306, respectively). The mean maximum load at failure indicated that the double row construct was significantly stronger than the single row construct. This was found to be true for both the extensor and flexor reattachment (213.6; SD 78.7 N versus 384.1; SD 105.6 N, P = 0.010 and 203.7; SD 65.8 N versus 318.0; SD 64.6 N, P = 0.013, respectively).

CONCLUSIONS

The double row technique provides significant greater stability to the reattached common flexor or extensor origin to the medial or lateral epicondyle. Thus, it should be considered in the development of improved repair techniques for stabilizers of the elbow.

STUDY

DESIGN

Controlled laboratory study.

Для цитирования: Lenich Andreas, Pfeifer Christian, Proier Philipp, Fleer Roman, Wijdicks Coen, Roth Martina, Martetschläger Frank, Pogorzelski Jonas. Reattachment of the flexor and extensor tendons at the epicondyle in elbow instability: a biomechanical comparison of techniques.. BMC musculoskeletal disorders. 2018. DOI: 10.1186/s12891-018-2341-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.