MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/scs.0000000000009471

Медицинская библиотека · The Journal of craniofacial surgery · 2023

Biomechanical Evaluation of a Standard Temporomandibular Joint Prosthesis and Screw Arrangement Optimization: A Finite Element Analysis.

Zhang Luzhu, Qin Haiyi, Abdelrehem Ahmed, He Dongmei

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

Artificial total joint replacement is an important method of temporomandibular joint (TMJ) reconstruction, which has been advocated for TMJ osteoarthrosis, ankylosis, tumors, and other diseases. We designed one type of standard TMJ prosthesis fit for Chinese patients. This study aimed to explore the biomechanical behavior of the standard TMJ prosthesis using finite element analysis and selects an optimal screw arrangement scheme for clinical application.

MATERIALS AND

METHODS

A female volunteer was recruited for a maxillofacial computed tomography scan, then the Hypermesh software was used to establish a finite element model of a mandibular condyle defect repaired with an artificial TMJ prosthesis. An advanced universal finite element program software was used to calculate the stress and deformation under a simulated maximum bite force loading. Also, the forces of screws under different numbers and arrangements were analyzed. Meanwhile, we designed an experiment to verify the calculation model.

RESULTS

The average maximum stress of the fossa component of the standard prosthesis model was 19.25 MPa. The average maximum stress of the condyle component was 82.58 MPa, mainly concentrated near the top row hole. The fossa component should be fixed with at least 3 screws, and the optimal number of screws was 4. The condyle component should be fixed with at least 4 screws, and its optimal number was 6. The best scheme of screw arrangement was determined. The results of the verification experiment showed that the analysis was reliable.

CONCLUSIONS

The stress distribution of the standard TMJ prosthesis is uniform, meanwhile, the number and arrangement of the screws significantly affect the contact force of the screws.

Для цитирования: Zhang Luzhu, Qin Haiyi, Abdelrehem Ahmed, He Dongmei. Biomechanical Evaluation of a Standard Temporomandibular Joint Prosthesis and Screw Arrangement Optimization: A Finite Element Analysis.. The Journal of craniofacial surgery. 2023. DOI: 10.1097/scs.0000000000009471.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.