MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14444/7123

Медицинская библиотека · JPMA. The Journal of the Pakistan Medical Association · 2015

Clinical predictors of mortality in hospitalized patients with infective endocarditis at a tertiary care center in Pakistan.

Coric Domagoj, Roybal Raphael R, Grubb Mark, Rossi Vincent, Yu Alex K, Swink Isaac R, Long Jason, Cheng Boyle C, Inzana Jason A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Expandable devices for transforaminal or posterior lumbar interbody fusion (TLIF and PLIF, respectively) may enable greater restoration of disc height, foraminal height, and stability within the interbody space than static spacers. Medial-lateral expansion may also increase stability and resistance to subsidence. This study evaluates the clinical and radiographic outcomes from early experience with a bidirectional expandable device.

METHODS

This was a retrospective analysis of a continuous series of patients across 3 sites who had previously undergone TLIF or PLIF surgery with a bidirectional expandable interbody fusion device (FlareHawk, Integrity Implants, Inc) at 1 or 2 contiguous levels between L2 and S1. Outcomes included the Oswestry Disability Index (ODI), a visual analog scale (VAS) for back pain or leg pain, radiographic fusion by 1 year of follow-up, subsidence, device migration, and adverse events (AE).

RESULTS

There were 58 eligible patients with radiographs for 1-year fusion assessments and 45 patients with ODI, VAS back pain, or VAS leg pain data at baseline and a mean follow-up of 4.5 months. The ODI, VAS back pain, and VAS leg pain scores improved significantly from baseline to final follow-up, with mean improvements of 14.6 ± 19.1, 3.4 ± 2.6, and 3.9 ± 3.4 points (P < .001 for each), respectively. In addition, 58% of patients achieved clinically significant improvements in ODI, 76% in VAS back pain, and 71% in VAS leg pain. By 1 year, 96.6% of patients and 97.4% of levels were considered fused. There were zero cases of device subsidence and 1 case of device migration (1.7%). There were zero device-related AEs, 1 intraoperative dural tear, and 3 subsequent surgical interventions.

CONCLUSIONS

The fusion rate, improvements in patient-reported outcomes, and the AEs observed are consistent with those of other devices. The bidirectional expansion mechanism may provide other important clinical value, but further studies will be required to elucidate the unique advantages.

LEVEL OF EVIDENCE: 4.

Для цитирования: Coric Domagoj, Roybal Raphael R, Grubb Mark, Rossi Vincent, Yu Alex K, Swink Isaac R, Long Jason, Cheng Boyle C, Inzana Jason A. Clinical predictors of mortality in hospitalized patients with infective endocarditis at a tertiary care center in Pakistan.. JPMA. The Journal of the Pakistan Medical Association. 2015. DOI: 10.14444/7123.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.