DOI 10.1016/j.jdent.2025.106134
Pull-out force and fracture load of fully sintered zirconia hybrid abutment-crowns on Ti-base abutments: Surface treatment effects and material comparison.
Аннотация
OBJECTIVES
To evaluate the effect of surface treatment on the pull-out force of implant restorations supported by Ti-bases and milled from fully sintered niobium oxide-containing yttria-stabilized tetragonal zirconia polycrystals ([Y, Nb]-TZP), and to compare their fracture load with that of lithium disilicate (LD) and polymer-infiltrated ceramic network (PICN) restorations.
METHODS
To evaluate pull-out force, 40 (Y, Nb)-TZP hybrid abutment-crown specimens were divided into four groups based on the surface treatment applied (n = 10): no surface treatment (FSZ-N group), airborne-particle abrasion (APA) (FSZ-A group), a 10-methacryloyloxydecyl dihydrogen phosphate (MDP) primer (FSZ-M group), and both APA and a 10-MDP primer (FSZ-AM group). After cementation and thermocycling, the pull-out forces and failure modes were examined by pull-out testing. To evaluate fracture load, 30 hybrid abutment-crown specimens were milled from (Y, Nb)-TZP (fully sintered zirconia; FSZ group), LD (LD group), and PICN (PICN group) blocks (n = 10). Following cementation and thermocycling, fracture loads and failure modes were recorded.
RESULTS
The FSZ-M and FSZ-AM groups demonstrated significantly higher pull-out forces than the FSZ-N group. The FSZ-A group showed the lowest pull-out force. The LD group had a higher fracture load than the PICN group. The fracture load of the FSZ group showed no significant difference compared with the LD or PICN group.
CONCLUSIONS
Applying a 10-MDP-containing primer enhanced the pull-out force of hybrid abutment-crowns milled from fully sintered (Y, Nb)-TZP, with or without APA. Implant restorations fabricated from this material and supported by Ti-base abutments exhibited a fracture load comparable to that of LD and PICN restorations.
CLINICAL SIGNIFICANCE: For implant restorations milled from fully sintered zirconia and supported by Ti-base abutments, applying a 10-MDP-containing primer is a key step for improving retention. Furthermore, their fracture load, which is comparable to other restorations milled from established materials, supports their potential for clinical use on Ti-base abutments.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.