MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bone.2025.117735

Медицинская библиотека · Bone · 2025

AI-supported opportunistic detection of vertebral fractures on routine CT scans: Diagnostic performance and clinical relevance.

Behanova Martina, Sokhan Anton, Haschka Judith, Zandieh Shahin, Salzlechner Christoph, Ljuhar Richard, Zwerina Jochen, Kocijan Roland

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Vertebral fractures (VFs) are among the most common osteoporotic fractures, yet they are frequently underdiagnosed and left untreated. The use of an artificial intelligence (AI) tool may support improved detection rates. This study aimed to evaluate the diagnostic performance of the AI-based software (IB Lab FLAMINGO) in identifying VFs on thoracic and abdominal CT scans, using radiologist assessment as the reference standard.

METHODS

This was a monocentric, retrospective cross-sectional study. 205 patients with CT scans performed for non-skeletal indications were randomly selected. Sensitivity, specificity, and accuracy were calculated at the vertebra and patient level. We examined the proportion of false positive AI-identified fractures that might represent overlooked fractures upon re-evaluation.

RESULTS

Among 205 patients (59 % male; mean age 67.9 ± 9.5 years), VFs were initially identified in 11.2 % by the radiologist, most frequently at the thoracolumbar junction. Females showed more thoracic (T4-T7) fractures, while males more commonly had lumbar (L1-L4) fractures. The AI analyzed 190 patients (92.7 %), detecting fractures in 24.7 %. At the patient level, IB Lab FLAMINGO showed 81 % accuracy, 74 % sensitivity and 82 % specificity. Vertebra-level performance (N = 3040) demonstrated high accuracy (97 %) and specificity (97 %). As a result of re-evaluation, fractures were confirmed in 29 of 30 AI-positively flagged patients, increasing sensitivity to 88.5 %, specificity to 99.3 %, and the overall presence of VFs to 25 %.

DISCUSSION: The performance metrics support potential use of AI IB Lab FLAMINGO as a screening aid and as a quality assurance tool, taking into account the proportion of missed diagnoses by the radiologist.

Для цитирования: Behanova Martina, Sokhan Anton, Haschka Judith, Zandieh Shahin, Salzlechner Christoph, Ljuhar Richard, Zwerina Jochen, Kocijan Roland. AI-supported opportunistic detection of vertebral fractures on routine CT scans: Diagnostic performance and clinical relevance.. Bone. 2025. DOI: 10.1016/j.bone.2025.117735.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.