MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/1516-3180.2021.0852.13062022

Медицинская библиотека · Sao Paulo medical journal = Revista paulista de medicina · 2022

Ultrasound techniques for the detection of developmental dysplasia of the hip: a systematic review and meta-analysis.

Duarte Marcio Luís, Motta Giovanna Galvão Braga, Rodrigues Natasha Vogel Majewski, Chiovatto Alessandra Rodrigues Silva, Chiovatto Eduardo Davino, Iared Wagner

МетаанализСистематический обзорСтатьяПеревод в очереди

Аннотация

BACKGROUND

Developmental dysplasia of the hip (DDH) encompasses a broad spectrum of hip pathologies, including femoral or acetabular dysplasia, hip instability, or both. According to the medical literature, ultrasonography is the most reliable diagnostic method for DDH. Several techniques for the assessment of hips in newborns and infants, using ultrasonography, have been described.

OBJECTIVE

To compare the accuracy of the Graf technique and other diagnostic techniques for DDH.

DESIGN AND

SETTING

A systematic review of studies that analyzed ultrasound techniques for the diagnosis of DDH within an evidence-based health program of a federal university in São Paulo (SP), Brazil.

METHODS

A systematic search of relevant literature was conducted in the PubMed, EMBASE, Cochrane Library, CINAHL, and LILACS databases for articles published up to May 5, 2020, relating to studies evaluating the diagnostic accuracy of different ultrasound techniques for diagnosing DDH. The QUADAS 2 tool was used for methodological quality evaluation.

RESULTS

All hips were analyzed using the Graf method as a reference standard. The Morin technique had the highest rate of sensitivity, at 81.12-89.47%. The Suzuki and Stress tests showed 100% specificity. The Harcke technique showed a sensibility of 18.21% and specificity of 99.32%.

CONCLUSION

All the techniques demonstrated at least one rate (sensibility and specificity) lower than 90.00% when compared to the Graf method. The Morin technique, as evaluated in this systematic review, is recommended after the Graf method because it has the highest sensitivity, especially with the three-pattern classification of 89.47%.

REGISTRATION NUMBER: Identifier: CRD42020189686 at the International Prospective Register of Systematic Reviews (identifier: CRD42020189686).

Для цитирования: Duarte Marcio Luís, Motta Giovanna Galvão Braga, Rodrigues Natasha Vogel Majewski, Chiovatto Alessandra Rodrigues Silva, Chiovatto Eduardo Davino, Iared Wagner. Ultrasound techniques for the detection of developmental dysplasia of the hip: a systematic review and meta-analysis.. Sao Paulo medical journal = Revista paulista de medicina. 2022. DOI: 10.1590/1516-3180.2021.0852.13062022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.