MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2017.10.037

Медицинская библиотека · The Journal of arthroplasty · 2017

Increased Serum Ion Levels After Ceramic-on-Metal Bearing Total Hip Arthroplasty: Influence of an Asian Lifestyle.

Han Seung-Beom, Oh Jong Keon, Jang Woo Young, Choudhary Nishant, Kim Hyun Gon, Shon Won Yong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Recent clinical studies have suggested that systemic metal ion levels are significantly elevated at midterm follow-up in patients with ceramic-on-metal (COM) bearing. However, it is not clear whether there is a correlation between patient-related factors including the lifestyle and elevated levels of serum metal ions following COM total hip arthroplasty (THA).

METHODS

Serum metal levels were measured in 201 patients (234 hips) including 121 COM patients (140 hips) and 80 non-COM patients (94 hips). The Harris Hip Score, University of California, Los Angeles activity scale score, and Western Ontario and McMaster Universities Osteoarthritis Index score were measured and radiographs were obtained for the analysis.

RESULTS

Significantly higher levels of cobalt (Co) and chromium (Cr) were detected in the serum of the COM THA group (Co: 1.86 ± 4.0 μg/L; Cr: 1.81 ± 2.87 μg/L) than those of the non-COM THA group (Co: 0.27 ± 0.14 μg/L; Cr: 0.19 ± 0.25 μg/L; P < .001). The serum metal levels of patients who achieved the squatting position and the kneeling position were significantly higher than those of patients who could not squat (Co: P = .033; Cr: P = .074) and kneel (Co: P = .049; Cr: P = .031). The metal ion levels of the COM THA group correlated with the total range of motion (Co: P = .0293; Cr: P = .0399).

CONCLUSION

Patients who underwent a 36-mm COM THA showed high serum metal levels although good clinical outcomes at the midterm follow-up. We found that COM THA patients who were capable of greater range of motion, squatting, and kneeling are at risk of metal ion-related problems.

Для цитирования: Han Seung-Beom, Oh Jong Keon, Jang Woo Young, Choudhary Nishant, Kim Hyun Gon, Shon Won Yong. Increased Serum Ion Levels After Ceramic-on-Metal Bearing Total Hip Arthroplasty: Influence of an Asian Lifestyle.. The Journal of arthroplasty. 2017. DOI: 10.1016/j.arth.2017.10.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.