m+Medelevator.RU
← Поиск публикаций
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2016

Development of a modified QuEChERS method for the determination of veterinary antibiotics in swine manure by liquid chromatography tandem mass spectrometry.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Guo Chunna, Wang Mingru, Xiao Hui, Huai Binbin, Wang Feng, Pan Guangfang, Liao Xiaoping, Liu Yahong

Аннотация

A QuEChERS (quick, easy, cheap, effective, rugged and safe) based methodology was developed for the rapid, simultaneous quantification and identification of 26 veterinary drugs in swine manure by liquid chromatography tandem mass spectrometry. The selected antibiotics included tetracyclines, sulfonamides, macrolides, fluoroquinolones, lincosamides and pleuromutilins. This is the first study to determine pleuromutilin levels in manure. The QuEChERS process involved two simple steps. First, sample extraction with methanol: acetonitrile: 0.1M EDTA-McIlvaine buffer followed by phase separation with MgSO4: NaCl addition. The supernatant was then extracted and cleaned by dispersive solid-phase extraction using a primary-secondary amine (PSA) and octadecylsilane (C18) support. The proposed method provides a linearity in the range of 1-500ngmL-1 and linear regression coefficients (r) were greater than 0.996. MDL and MQL ranged between 0.01-1.86μgkg(-1) and 0.05-5.91μgkg(-1), respectively. Recoveries ranged from 61.39 to 105.65% with the exception of sulfaquinoxaline (55.7-56.8%) and valnemulin (33.7-37.7%). This method resulted in good precision (repeatability and reproducibility) and relative standard deviations less than 17% within the same day, and lower than 20% between days. The method was then applied to study the swine manure samples collected from Guangdong, China. Chlortetracycline, tetracycline, doxycycline, sulfadimidine and tilmicosin were detected in all samples indicating high residuals in manure. In fact tilmicosin was detected at 14400μgkg(-1) suggesting that prudent treatment of manure should be conducted to prevent environmental contamination. In conclusion, this workflow can provide a simpler and more cost-effective alternative to conventional methods and is compatible with processing large sample numbers over a short time period.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты