The Journal of bone and joint surgery. American volume · 2014
Preliminary results of a new test for rapid diagnosis of septic arthritis with use of leukocyte esterase and glucose reagent strips.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Omar Mohamed, Ettinger Max, Reichling Moritz, Petri Maximilian, Lichtinghagen Ralf, Guenther Daniel, Suero Eduardo M, Jagodzinski Michael, Krettek Christian
Аннотация
BACKGROUND: Most currently used tools to diagnose septic arthritis are either not readily available or fail to provide real-time results. Reagent strip tests have identified infections in various body fluids. We hypothesized that combined leukocyte esterase and glucose strip tests can aid in diagnosing septic arthritis in native synovial fluid because (1) leukocyte esterase concentrations would be elevated at the infection site because of secretion by recruited neutrophils, and (2) glucose concentrations would be reduced because of bacterial metabolism.
METHODS: We prospectively investigated synovial fluid from consecutive patients with an atraumatic joint effusion who underwent arthrocentesis in our emergency department during a one-year period. Leukocyte esterase and glucose strip tests were performed on the synovial fluid. Synovial fluid leukocyte count, crystal analysis, Gram staining, culture, and glucose concentration results were also assessed.
RESULTS: Nineteen fluids were classified as septic and 127 as aseptic. Considering septic arthritis to be present when the leukocyte esterase reading was positive (++ or +++) and the glucose reading was negative (-) yielded a sensitivity of 89.5% (95% confidence interval [CI], 66.9% to 98.7%), specificity of 99.2% (95% CI, 95.7% to 99.9%), positive predictive value of 94.4% (95% CI, 72.7% to 99.9%), negative predictive value of 98.4% (95% CI, 94.5% to 99.8%), positive likelihood ratio of 114, and negative likelihood ratio of 0.11. The synovial leukocyte counts and polymorphonuclear cell percentages were consistent with the semiquantitative readings on the leukocyte esterase strip tests, and the glucose concentrations were consistent with the glucose strip test results.
CONCLUSIONS: Combined leukocyte esterase and glucose strip tests can be a useful additional tool to help confirm or rule out a diagnosis of septic arthritis.
METHODS: We prospectively investigated synovial fluid from consecutive patients with an atraumatic joint effusion who underwent arthrocentesis in our emergency department during a one-year period. Leukocyte esterase and glucose strip tests were performed on the synovial fluid. Synovial fluid leukocyte count, crystal analysis, Gram staining, culture, and glucose concentration results were also assessed.
RESULTS: Nineteen fluids were classified as septic and 127 as aseptic. Considering septic arthritis to be present when the leukocyte esterase reading was positive (++ or +++) and the glucose reading was negative (-) yielded a sensitivity of 89.5% (95% confidence interval [CI], 66.9% to 98.7%), specificity of 99.2% (95% CI, 95.7% to 99.9%), positive predictive value of 94.4% (95% CI, 72.7% to 99.9%), negative predictive value of 98.4% (95% CI, 94.5% to 99.8%), positive likelihood ratio of 114, and negative likelihood ratio of 0.11. The synovial leukocyte counts and polymorphonuclear cell percentages were consistent with the semiquantitative readings on the leukocyte esterase strip tests, and the glucose concentrations were consistent with the glucose strip test results.
CONCLUSIONS: Combined leukocyte esterase and glucose strip tests can be a useful additional tool to help confirm or rule out a diagnosis of septic arthritis.