Clinical Application of Personalized Digital Surgical Planning and Precise Execution for Severe and Complex Adult Spinal Deformity Correction Utilizing 3D Printing Techniques.
Аннотация
(1)
Background
The three-dimensional printing (3DP) technique has been reported to be of great utility in spine surgery. The purpose of this study is to report the clinical application of personalized preoperative digital planning and a 3DP guidance template in the treatment of severe and complex adult spinal deformity. (2)
Methods
eight adult patients with severe rigid kyphoscoliosis were given personalized surgical simulation based on the preoperative radiological data. Guidance templates for screw insertion and osteotomy were designed and manufactured according to the planning protocol and used during the correction surgery. The perioperative, and radiological parameters and complications, including surgery duration, estimated blood loss, pre- and post-operative cobb angle, trunk balance, and precision of osteotomy operation with screw implantation were collected retrospectively and analyzed to evaluate the clinical efficacy and safety of this technique. (3)
Results
Of the eight patients, the primary pathology of scoliosis included two adult idiopathic scoliosis (ADIS), four congenital scoliosis (CS), one ankylosing spondylitis (AS), and one tuberculosis (TB). Two patients had a previous history of spinal surgery. Three pedicle subtraction osteotomies (PSOs) and five vertebral column resection (VCR) osteotomies were successfully performed with the application of the guide templates. The main cobb angle was corrected from 99.33° to 34.17°, and the kyphosis was corrected from 110.00° to 42.00°. The ratio of osteotomy execution and simulation was 97.02%. In the cohort, the average screw accuracy was 93.04%. (4)
Conclusions
The clinical application of personalized digital surgical planning and precise execution via 3D printing guidance templates in the treatment of severe adult rigid deformity is feasible, effective, and easily generalizable. The preoperative osteotomy simulation was executed with high precision, utilizing personalized designed guidance templates. This technique can be used to reduce the surgical risk and difficulty of screw placement and high-level osteotomy.