Intraoperative evaluation of the effects of femoral component offset and head size on joint stability in total hip arthroplasty.
Аннотация
PURPOSE: To evaluate intraoperatively the effects of femoral offset and head size on stability of the hip joints in total hip arthroplasty (THA) via posterior approach.
METHODS
Thirty cementless THAs were included in this study. After acetabular shell and femoral broach fixation, trial reduction was repeated using a femoral neck (5- to 8-mm higher or standard offset) and a head (26 mm or 32 mm). To evaluate joint stability, range of internal rotation (IR) in hip flexion prior to posterior subluxation and range of external rotation (ER) in hip extension were measured.
RESULTS
The high-offset neck provided significantly (approximately 10°) greater range of IR to subluxation than the standard-offset neck. No hips ended in anterior subluxation by ER. The head size did not have significant effects on the stability.
CONCLUSION
Results suggest that the 5- to 8-mm greater femoral offset might be effective in preventing instability in primary THA.