MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0175366

Медицинская библиотека · PloS one · 2017

Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head.

Wang Wei, Hu Wei, Yang Pei, Dang Xiao Qian, Li Xiao Hui, Wang Kun Zheng

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Core decompression is an efficient treatment for early stage ischemic necrosis of the femoral head. In conventional procedures, the pre-operative X-ray only shows one plane of the ischemic area, which often results in inaccurate drilling. This paper introduces a new method that uses computer-assisted technology and rapid prototyping to enhance drilling accuracy during core decompression surgeries and presents a validation study of cadaveric tests.

METHODS

Twelve cadaveric human femurs were used to simulate early-stage ischemic necrosis. The core decompression target at the anterolateral femoral head was simulated using an embedded glass ball (target). Three positioning Kirschner wires were drilled into the top and bottom of the large rotor. The specimen was then subjected to computed tomography (CT). A CT image of the specimen was imported into the Mimics software to construct a three-dimensional model including the target. The best core decompression channel was then designed using the 3D model. A navigational template for the specimen was designed using the Pro/E software and manufactured by rapid prototyping technology to guide the drilling channel. The specimen-specific navigation template was installed on the specimen using positioning Kirschner wires. Drilling was performed using a guide needle through the guiding hole on the templates. The distance between the end point of the guide needle and the target was measured to validate the patient-specific surgical accuracy.

RESULTS

The average distance between the tip of the guide needle drilled through the guiding template and the target was 1.92±0.071 mm.

CONCLUSIONS

Core decompression using a computer-rapid prototyping template is a reliable and accurate technique that could provide a new method of precision decompression for early-stage ischemic necrosis.

Для цитирования: Wang Wei, Hu Wei, Yang Pei, Dang Xiao Qian, Li Xiao Hui, Wang Kun Zheng. Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head.. PloS one. 2017. DOI: 10.1371/journal.pone.0175366.