BACKGROUND

Only a few studies have used in/opposed phase method for a quantitative evaluation of fat fraction in the spine.

PURPOSE: To compare multivoxel proton MR spectroscopy and chemical-shift gradient-echo MR imaging for bone marrow fat quantification in vertebral compression fractures (VCF).

MATERIAL AND

METHODS

Vertebral marrow fat quantification in fifteen patients was measured at 3.0-T. Multi-voxel proton spectroscopy (MRS) and in/opposed-phase MR imaging using a fat map build with a triple-echo gradient-echo sequence was used. All the patients had benign vertebral collapse. Bone marrow fat content was evaluated by both techniques in compressed (acute or chronic) and in non-compressed vertebrae.

RESULTS

The percentage of fat fraction measured by the triple-echo sequence was well correlated with those calculated by MRS (r(2) = 0.85; P < 10(-4)). There was a significant decrease of fat fraction in acute VCF versus both chronic VCF (P < 10(-9)) and non-fractured vertebrae (P < 10(-7)). There was no significant difference in fat fraction evaluated by both techniques between non-fractured vertebrae and chronic VCF.

CONCLUSION

We have validated the in/opposed phase method compared with MRS for vertebral bone marrow fat quantification. The fat mapping using a triple-echo gradient-echo sequence allows distinguishing acute and chronic benign VCF.

Для цитирования: Régis-Arnaud Anne, Guiu Boris, Walker Paul-Michael, Krausé Denis, Ricolfi Frédéric, Ben Salem Douraied. Bone marrow fat quantification of osteoporotic vertebral compression fractures: comparison of multi-voxel proton MR spectroscopy and chemical-shift gradient-echo MR imaging.. Acta radiologica (Stockholm, Sweden : 1987). 2011. DOI: 10.1258/ar.2011.100412.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.